Datasheet summary
CSM RE16040-FLR
Engineering summary from PDF text extraction for CSM RE16040-FLR. Verify every value with the OEM datasheet.
Summary
Product identification
- Model Name: RE 16040-FLR
- Description: Fouling resistant RO element with low pressure for brackish water and wastewater reuse
- Permeate flow rate: 36,000 GPD (136.1 m³/day)
- Nominal salt rejection: 99.6%
- Effective membrane area: 1,600 ft² (148.6 m²)
- Membrane type: Thin-Film Composite
- Membrane material: Polyamide (PA)
- Element configuration: Spiral-Wound, FRP Wrapping
Performance Test Conditions: The stated product performance is based on data taken after 30 minutes of operation at the following test conditions:
- 1,500 mg/L NaCl solution at 150 psig (1.0 MPa) applied pressure
- 15% recovery
- 77 °F (25 °C)
- pH 6.5–7.0
- Minimum salt rejection is 99.5%.
- Permeate flow rate for each element may vary but will be no more than 15%.
Operating limits
- Max. Pressure Drop / Element: 15 psi (0.1 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 252 gpm (57.2 m³/hr)
- Min. Concentrate Flow Rate: 64 gpm (14.5 m³/hr)
- Max. Operating Temperature: 113 °F (45 °C)
- Operating pH Range: 2.0–11.0
- CIP pH Range: 1.0–13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
Feed water
Saturation Limits (Using Antiscalants):
- Langlier Saturation Index (LSI): < +1.5
- Stiff and Davis Saturation Index (SDSI): < +0.5
- CaSO₄: 230% saturation
- SrSO₄: 800% saturation
- BaSO₄: 6,000% saturation
- SiO₂: 100% saturation
Note: The above saturation limits are typically accepted by proprietary antiscalant manufacturers. It is the user’s responsibility to ensure proper chemical(s) and concentration are dosed ahead of the membrane system to prevent scale formation anywhere within the membrane system.
Mechanical / hydraulic
- Dimensions:
- A: 40.0 inch (1,016 mm)
- B: 16.0 inch (402 mm)
- C: 3.0 inch (77 mm)
- Weight: 60 kg
- Part Number (Inter-connector): 40000219
- Part Number (O-ring): 40000220
Notes:
- Each membrane element is supplied with one interconnector (coupler) and five o-rings.
- All RE16040 elements fit nominal 16.0 inch (402 mm) I.D. pressure vessels.
General Handling Procedures
- Elements contained in the boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight. If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
- Permeate from the first hour of operation should be discarded to flush out the preservative solution.
- Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short-term storage (i.e., one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
- Permeate pressure must always be equal or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
Packaging
- All elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution and individually packaged in a cardboard box.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions of the OEM PDF datasheet. For contractual data and complete specifications, the official OEM PDF revision used on the project must be consulted.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.