Datasheet summary
CSM RE1810-30
Engineering summary from PDF text extraction for CSM RE1810-30. Verify every value with the OEM datasheet.
Summary
Product identification
These are residential reverse osmosis (RO) elements, 1.8 inches in diameter.
- Membrane type: Thin-Film Composite
- Membrane material: Polyamide (PA)
- Element configuration: Spiral-Wound, Tape Wrapping
Operating limits
- Max. Operating Pressure: 125 psi (0.86 MPa)
- Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
- Max. Operating Temperature: 113 °F (45 °C)
- Operating pH Range: 2.0–11.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
Product water
The stated product performance is based on data taken after 30 minutes of operation at the following test conditions:
-
200 mg/L NaCl solution
-
60 psig (0.41 MPa) applied pressure
-
15% recovery
-
77 °F (25 °C)
-
pH 6.5–7.0
-
Minimum salt rejection: 96.0%
-
Permeate flow rate for each element may vary but will be no more than 15%.
Permeate Flow Rate and Salt Rejection:
- RE1810-30: 30 GPD (114 L/day), 98.0% Salt Rejection
- RE1810-50: 50 GPD (189 L/day), 98.0% Salt Rejection
- RE1812-35: 35 GPD (132 L/day), 98.0% Salt Rejection
- RE1812-50: 50 GPD (189 L/day), 98.0% Salt Rejection
- RE1812-60: 60 GPD (227 L/day), 98.0% Salt Rejection
- RE1812-80: 80 GPD (303 L/day), 98.0% Salt Rejection
Mechanical / hydraulic
- Element configuration: Spiral-Wound, Tape Wrapping
Dimensions (in / mm):
- Models RE1810-30, RE1810-50:
- A: 0.67 in (17 mm)
- B: 0.55 in (14 mm)
- C: 10.08 in (256 mm)
- D: 0.98 in (25 mm)
- E: 1.77 in (45 mm)
- Models RE1812-35, RE1812-50, RE1812-60, RE1812-80:
- A: 0.67 in (17 mm)
- B: 0.87 in (22 mm)
- C: 11.73 in (298 mm)
- D: 0.98 in (25 mm)
- E: 1.77 in (45 mm)
Packaging and Handling Procedures
- Elements must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
- If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
- Permeate from the first hour of operation should be discarded to flush out the preservative solution.
- Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short-term storage (i.e., one week or less), 1% by weight sodium metabisulfite solution is adequate.
- Keep elements moist at all times after initial wetting.
- Only use chemicals compatible with the membrane elements and components.
- Permeate pressure must always be equal to or less than the feed/concentrate pressure.
Certifications
- Dry type elements are vacuum leak tested using the San Diego Protocol.
- These model names are tested and certified under NSF/ANSI standard 58, material requirement only (excluding RE1810-30).
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.