Back to CMS Membranes
Toray logo

Datasheet summary

CSM RE1812-CE60

Engineering summary from PDF text extraction for CSM RE1812-CE60. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model Name: RE1812-CE60
  • Description: Innovative chlorine resistant RO element for residential use
  • Membrane type: Thin-Film Composite
  • Membrane material: Polyamide (PA)
  • Element configuration: Spiral-Wound, Tape Wrapping

Performance Specifications

  • Permeate Flow Rate: 60 GPD (227 L/day)
  • Salt Rejection: 98%

Test Conditions: The stated product performance is based on data taken after 30 minutes of operation at the following test conditions:

  • 200 mg/L NaCl solution
  • 60 psig (0.41 MPa) applied pressure
  • 15% recovery
  • 77 °F (25 °C)
  • pH 6.5–7.0
  • Permeate flow rate for each element may vary but will be no more than 15%.

Packaging:

  • Dry elements are packaged in a polyethylene bag.
  • Wet elements are packaged in a polyethylene bag containing SB (4g/L) + HCl (0.51g/L) solution.

Mechanical / Hydraulic

Dimensions (all measurements in inches, with mm in parentheses):

  • Model Name: RE1812-CE60
  • A: 0.67 (17mm)
  • B: 0.87 (22mm)
  • C: 11.73 (298mm)
  • D: 0.98 (25mm)
  • E: 1.77 (45mm)

Operating Limits

  • Max. Operating Pressure: 125 psi (0.86 MPa)
  • Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0–11.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

General Handling Procedures

  • Elements contained in the boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
  • If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
  • Permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short term storage (i.e., one week or less) 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
  • Keep elements moist at all times after initial wetting.
  • Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
  • Permeate pressure must always be equal or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.