Datasheet summary

CSM RE2540-BN

Engineering summary from PDF text extraction for CSM RE2540-BN. Verify every value with the OEM datasheet.

Summary

Product Identification

The RE 2540-BN is a normal-grade reverse osmosis (RO) element featuring a thick feed spacer, designed for brackish water applications.

  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, FRP Wrapping

Performance Specifications

The stated product performance is based on data taken after 30 minutes of operation under specific test conditions.

  • Permeate Flow Rate: 600 GPD (2.3 m³/day)
  • Stabilized Salt Rejection: 99.7%
  • Minimum Salt Rejection: 99.4%
  • Effective Membrane Area: 24 ft² (2.5 m²)

Test Conditions:

  • NaCl Solution: 2,000 mg/L
  • Applied Pressure: 225 psig (1.5 MPa)
  • Recovery: 15%
  • Temperature: 77 °F (25 °C)
  • pH: 6.5 – 7.0

Note: Permeate flow rate for each element may vary but will be no more than 15%.

Operating Limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 6 gpm (1.36 m³/hr)
  • Min. Concentrate Flow Rate: 1 gpm (0.23 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0 – 11.0
  • CIP pH Range: 1.0 – 13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Design Guidelines for Various Water Sources

  • Wastewater Conventional (SDI < 5): 8–12 gfd
  • Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
  • Seawater, Open Intake (SDI < 5): 7–10 gfd
  • Seawater, Beach Well (SDI < 3): 8–12 gfd
  • Surface Water (SDI < 5): 12–16 gfd
  • Surface Water (SDI < 3): 13–17 gfd
  • Well Water (SDI < 3): 13–17 gfd
  • RO Permeate (SDI < 1): 21–30 gfd

Saturation Limits (Using Antiscalants)

  • Langlier Saturation Index (LSI): < +1.5
  • Stiff and Davis Saturation Index (SDSI): < +0.5
  • CaSO₄: 230% saturation
  • SrSO₄: 800% saturation
  • BaSO₄: 6,000% saturation
  • SiO₂: 100% saturation

Mechanical / Hydraulic

The RE 2540-BN element fits nominal 2.5 inch (64 mm) I.D. pressure vessels. Each membrane element is supplied with one brine seal, one interconnector (coupler), and four o-rings.

Model NameA (Length)B (Diameter)C (Brine Tube Dia.)D (Endcap Dia.)E (Endcap Dia.)Part NumberInter-connectorBrine Seal
RE 2540-BN40.0 inch (1,016 mm)2.5 inch (64 mm)0.75 inch (19.1 mm)1.1 inch (28 mm)1.1 inch (28 mm)4000030540000223

Note: Dimensions C, D, and E appear to relate to the element's internal/endcap configurations. See the official PDF for exact tabulated values and diagrams.

General Handling Procedures

  • Elements should be stored dry at room temperature (7–32 °C; 40–95 °F) and out of direct sunlight.
  • If the polyethylene bag is damaged, add a new sodium bisulfite preservative solution and seal tightly to prevent drying and biological growth.
  • The permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Elements must be kept moist after initial wetting.
  • During storage, shipping, and system shutdowns, immerse elements in a preservative solution (e.g., 1% by weight sodium bisulfite or food-grade sodium metabisulfite) to prevent biological growth and freezing. For short-term storage (one week or less), 1% by weight sodium metabisulfite solution is sufficient.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components; incompatible chemicals may void the warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure; damage from permeate back pressure voids the warranty.