Back to CMS Membranes
Toray logo

Datasheet summary

CSM RE2540-SHF

Engineering summary from PDF text extraction for CSM RE2540-SHF. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: RE 2540-SHF
  • Application: High productivity RO element for seawater and high salinity well water.

Specifications

  • Permeate flow rate: 600 GPD (2.3 m³/day)
  • Stabilized salt rejection: 99.7%
  • Effective membrane area: 24 ft² (2.2 m²)
  • Minimum salt rejection: 99.6%
  • Membrane type: Thin-Film Composite
  • Membrane material: Polyamide (PA)
  • Element configuration: Spiral-Wound, FRP Wrapping

Test Conditions (for stated product performance)

  • 32,000 mg/L NaCl solution
  • 800 psig (5.5 MPa) applied pressure
  • 8% recovery
  • 77 °F (25 °C)
  • pH 6.5 – 7.0

Notes on Specifications

  • Permeate flow rate for each element may vary but will be no more than 20%.
  • All elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution and individually packaged in a cardboard box.

Dimensions

Model NameABCDEPart Number (Inter-connector)Part Number (Brine Seal)
RE 2540-SHF40.0 inch (1,016 mm)2.5 inch (64 mm)0.75 inch (19.1 mm)1.1 inch (28 mm)1.1 inch (28 mm)4000030540000223

Notes on Dimensions

  • Each membrane element is supplied with one brine seal, one interconnector (coupler), and four o-rings.
  • All RE2540 elements fit nominal 2.5 inch (64 mm) I.D. pressure vessels.

Operating Limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 1,200 psi (8.27 MPa)
  • Max. Feed Flow Rate: 6 gpm (1.36 m³/hr)
  • Min. Concentrate Flow Rate: 1 gpm (0.23 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0 – 11.0
  • CIP pH Range: 1.0 – 13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Feed Water

Design Guidelines for Various Water Sources (Flux in gfd)

  • Wastewater Conventional (SDI < 5): 8–12 gfd
  • Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
  • Seawater, Open Intake (SDI < 5): 7–10 gfd
  • Seawater, Beach Well (SDI < 3): 8–12 gfd
  • Surface Water (SDI < 5): 12–16 gfd
  • Surface Water (SDI < 3): 13–17 gfd
  • Well water (SDI < 3): 13–17 gfd
  • RO permeate (SDI < 1): 21–30 gfd

Saturation Limits (Using Antiscalants)

  • Langlier Saturation Index (LSI): < +1.5
  • Stiff and Davis Saturation Index (SDSI): < +0.5
  • CaSO₄: 230% saturation
  • SrSO₄: 800% saturation
  • BaSO₄: 6,000% saturation
  • SiO₂: 100% saturation

General Handling Procedures

  • Elements contained in the boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
  • If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
  • Permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing.
  • The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short-term storage (one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Disclaimer This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.