Summary

Product identification

The RE2812-300 is a residential reverse osmosis (RO) element, certified to NSF/ANSI 58.

  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, Tape Wrapping
  • Elements can be supplied as dry or wet-type. Wet-tested elements are soaked in a 1.0% food grade SBS preservative solution and vacuum sealed. All elements are individually boxed.

Operating limits

  • Max. Operating Pressure: 150 psi (1.03 MPa)
  • Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
  • Max. Operating Temperature: 113°F (45°C)
  • Operating pH Range: 2.0 – 11.0

Feed water

  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 3.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Product water

  • Permeate Flow Rate: 350 GPD (1,325 L/day)
  • NaCl Rejection: 97% (Minimum 95%)

Test Conditions (for stated performance):

  • 200 mg/L NaCl solution
  • 60 psig (0.41 MPa) applied pressure
  • 15% recovery
  • 77℉ (25℃)
  • pH 6.5–7.0
  • Permeate flow rate for each element may vary +25 / -15%.
  • Minimum salt rejection is 95.0%.
  • All elements are vacuum leak tested using the CSM integrity test.

Mechanical / hydraulic

Dimensions for model RE2812-300:

  • A: 0.67 inch (17 mm)
  • B: 0.87 inch (22 mm)
  • C: 11.73 inch (298 mm)
  • D: 0.87 inch (22 mm)
  • E: 2.93 inch (74.5 mm)

General Handling Procedures:

  • Elements in boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
  • For WET-TYPE elements, a 1% sodium metabisulfite solution is added to prohibit the growth of micro-organisms.
  • Permeate from the first hour of operation should be discarded.
  • Stabilized salt rejection is generally achieved within 1~48 hours of continuous use.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components; use of incompatible chemicals may void the limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the limited warranty.

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. Contractual data must always match the OEM PDF revision used on the project.