Back to CMS Membranes
Toray logo

Datasheet summary

CSM RE4040-BLN

Engineering summary from PDF text extraction for CSM RE4040-BLN. Verify every value with the OEM datasheet.

Summary

Product Identification

The RE4040-BLN is a low-pressure grade reverse osmosis (RO) element designed for brackish water applications. It features low-energy consumption.

Test Conditions

Performance is tested under the following conditions:

  • NaCl solution concentration: 1,500 mg/L
  • Applied pressure: 150 psig (1.03 MPa)
  • Recovery: 15%
  • Temperature: 77°F (25°C)
  • pH: 6.5–7.0
  • Permeate flow rate for each element may vary +25 / -15%.

General Features

  • Permeate Flow Rate: 2,600 GPD (9.8 m³/day)
  • Nominal Salt Rejection: 99.4% (Minimum 99.3%)
  • Effective Membrane Area: 85 ft² (7.9 m²)
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, FRP Wrapping

Operating Limits

  • Max. Pressure Drop / Element: 15 psi (0.10 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 18 gpm (4.09 m³/hr)
  • Min. Concentrate Flow Rate: 4 gpm (0.91 m³/hr)
  • Max. Operating Temperature: 113°F (45°C)
  • Operating pH Range: 2.0 – 11.0
  • CIP pH Range: 1.0 – 13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Application Data

This product is suitable for:

  • Industrial
  • Municipal
  • Semiconductor applications

Mechanical / Hydraulic

  • Model Name: RE4040-BLN
  • Dimensions:
    • A (Length): 40.0 inch (1,016 mm)
    • B (Diameter): 3.9 inch (99 mm)
    • C (Permeate tube ID): 0.75 inch (19 mm)
    • D/E (Permeate tube OD): 1.05 inch (26.7 mm)
  • Part Number (Inter-Connector): SWA01050
  • Part Number (Brine Seal): SWA01046
  • Each membrane element is supplied with one interconnector (coupler) and four O-rings.
  • All RE4040 elements fit nominal 4.0 inch (101.6 mm) I.D. pressure vessels.

General Handling Procedures

  • Elements must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
  • For WET-TYPE elements, a preservative solution (1% sodium metabisulfite solution) is added to prohibit microorganism growth.
  • Permeate from the first hour of operation should be discarded.
  • Stabilized salt rejection is generally achieved within 1–48 hours of continuous use.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components, as use of incompatible chemicals may void the limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element's limited warranty.
  • The element shell is FRP (Fiber Reinforced Plastic). Be aware of glass fiber strands and use safety equipment.

Certification

  • Certified to NSF/ANSI/CAN 61.