Datasheet summary

CSM RE4040-BLR

Engineering summary from PDF text extraction for CSM RE4040-BLR. Verify every value with the OEM datasheet.

Summary

Product identification

The CSM RE4040-BLR is a low-pressure grade reverse osmosis (RO) element designed for brackish water applications.

It features:

  • Low-Energy Consumption
  • High Permeate Flow and High Rejection

General Specifications:

  • Permeate Flow Rate: 2,100 GPD (7.9 m³/day)
  • Nominal Salt Rejection: 99.6% (Minimum 99.5%)
  • Effective Membrane Area: 85 ft² (7.9 m²)
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, FRP Wrapping

Applications include Industrial, Municipal, and Semiconductor.

Standard Test Conditions

Unless otherwise specified, performance data is measured under the following conditions:

  • NaCl Solution: 1,500 mg/L
  • Applied Pressure: 150 psig (1.03 MPa)
  • Recovery: 15%
  • Temperature: 77℉ (25℃)
  • pH: 6.5–7.0
  • Permeate flow rate for each element may vary but will be no more than -5%.

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.10 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 18 gpm (4.09 m³/hr)
  • Min. Concentrate Flow Rate: 4 gpm (0.91 m³/hr)
  • Max. Operating Temperature: 113°F (45°C)
  • Operating pH Range: 2.0 – 11.0
  • CIP pH Range: 1.0 – 13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Mechanical / hydraulic

Dimensions:

  • RE4040-BLR:
    • A (Length): 40.0 inch (1,016 mm)
    • B (Diameter): 3.9 inch (99.0 mm)
    • C (Interconnector Length): 0.75 inch (19.1 mm)
    • D/E (Brine Seal Diameter): 1.05 inch (26.7 mm)
  • Inter-Connector Part Number: SWA01050
  • Brine Seal Part Number: SWA01046

Notes:

  1. Each membrane element is supplied with one interconnector (coupler) and four O-rings.
  2. All RE4040 elements fit nominal 4.0 inch (101.6 mm) I.D. pressure vessels.

General Handling Procedures

  • Elements contained in boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
  • For WET-TYPE elements, a 1% sodium metabisulfite solution is added as a preservative.
  • Permeate from the first hour of operation should be discarded.
  • Stabilized salt rejection is generally achieved within 1–48 hours of continuous use.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components. Use of incompatible chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
  • The element shell is FRP (Fiber Reinforced Plastic). Be aware of glass fiber strands and use safety equipment.

Certifications

  • Certified to NSF/ANSI/CAN 61

Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or revisions not present in this extract. Contractual data must always match the specific OEM PDF revision used on the project.