Back to CMS Membranes
Toray logo

Datasheet summary

CSM RE8040-BLN

Engineering summary from PDF text extraction for CSM RE8040-BLN. Verify every value with the OEM datasheet.

Summary

Product identification

The CSM RE8040-BLN is a low-pressure grade reverse osmosis (RO) element designed for brackish water applications. It is characterized by low energy consumption.

  • Model Name: RE8040-BLN
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, FRP Wrapping
  • Certifications: Certified to NSF/ANSI/CAN 61
  • Applications: Industrial, Municipal, Semiconductor

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.10 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
  • Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
  • Max. Operating Temperature: 113°F (45°C)
  • Operating pH Range: 2.0 – 11.0
  • CIP pH Range: 1.0 – 13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Test Conditions

Performance specifications are based on the following test conditions:

  • NaCl solution: 1,500 mg/L
  • Applied pressure: 150 psig (1.03 MPa)
  • Recovery: 15%
  • Temperature: 77°F (25°C)
  • pH: 6.5–7.0

Product water

  • Permeate Flow Rate: 12,000 GPD (45.4 m³/day)
    • Permeate flow rate for each element may vary +25 / -15%.
  • Nominal Salt Rejection: 99.5% (Minimum 99.4%)
    • Stabilized salt rejection is generally achieved within 1~48 hours of continuous use.

Mechanical / hydraulic

  • Effective Membrane Area: 400 ft² (37.2 m²)
  • Dimensions:
    • A (Length): 40.0 inch (1,016 mm)
    • B (Diameter): 7.9 inch (200 mm)
    • C (Permeate tube ID): 1.12 inch (28.5 mm)
  • Weight: 15 kg
  • Fitting:
    • All RE8040 elements fit nominal 8.0 inch (203.2 mm) I.D. pressure vessels.
    • Each membrane element is supplied with one interconnector (coupler) and four O-rings.
  • Component Part Numbers:
    • Inter-Connector: SWA01049
    • Brine Seal: SWA01043
  • Element Shell: FRP (Fiber Reinforced Plastic).

General Handling Procedures and Warnings

  • Elements contained in boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
  • For WET-TYPE elements, a preservative solution (1% sodium metabisulfite solution) is added to prohibit the growth of micro-organisms.
  • Permeate from the first hour of operation should be discarded.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
  • The element shell is FRP (Fiber Reinforced Plastic). Be aware of glass fiber strands and use safety equipment.

Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions. Contractual data must always match the OEM PDF revision used on the project.

Official datasheet (PDF)