Datasheet summary
CSM RE8040-FD
Engineering summary from PDF text extraction for CSM RE8040-FD. Verify every value with the OEM datasheet.
Summary
Product Identification
The RE8040-FDn is an enhanced fouling resistant reverse osmosis (RO) element with a thick feed spacer, designed for wastewater reuse applications.
- Membrane type: Thin-Film Composite
- Membrane material: Polyamide (PA)
- Element configuration: Spiral-Wound, FRP Wrapping
General Features
- Permeate flow rate: 10,000 GPD (39.7 m³/day)
- Nominal salt rejection: 99.7%
- Effective membrane area: 380 ft² (35.3 m²)
- Feed spacer thickness: 34 mil
Product performance is based on 30 minutes of operation at the following test conditions:
- NaCl solution: 2,000 mg/L
- Applied pressure: 225 psig (1.5 MPa)
- Recovery: 15%
- Temperature: 77 °F (25 °C)
- pH: 6.5 – 7.0
Additional specifications:
- Minimum salt rejection: 99.4%
- Permeate flow rate variation: No more than 15%
- Packaging: Vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution, and individually packaged in a cardboard box.
Mechanical / Hydraulic
The RE8040-FDn element fits nominal 8.0 inch (201 mm) I.D. pressure vessels. Each element is supplied with one brine seal, one interconnector (coupler), and four o-rings.
| Model Name | A | B | C | Weight | Part Number |
|---|---|---|---|---|---|
| RE 8040-FDn | 40.0 inch | 8.0 inch | 1.12 inch | 15 kg | 40000308 |
| (1,016 mm) | (201 mm) | (28 mm) | 40000309 |
Operating Limits
- Max. Pressure Drop / Element: 15 psi (0.1 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
- Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
- Max. Operating Temperature: 113 °F (45 °C)
- Operating pH Range: 2.0–11.0
- CIP pH Range: 1.0–13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
Design Guidelines for Various Water Sources
- Wastewater Conventional (SDI < 5): 8–12 gfd
- Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
- Seawater, Open Intake (SDI < 5): 7–10 gfd
- Seawater, Beach Well (SDI < 3): 8–12 gfd
- Surface Water (SDI < 5): 12–16 gfd
- Surface Water (SDI < 3): 13–17 gfd
- Well water (SDI < 3): 13–17 gfd
- RO permeate (SDI < 1): 21–30 gfd
Saturation Limits (Using Antiscalants)
- Langlier Saturation Index (LSI): < +1.5
- Stiff and Davis Saturation Index (SDSI): < +0.5
- CaSO₄: 230% saturation
- SrSO₄: 800% saturation
- BaSO₄: 6,000% saturation
- SiO₂: 100% saturation
The above saturation limits are typically accepted by proprietary antiscalant manufacturers. It is the user’s responsibility to ensure proper chemical(s) and concentration are dosed ahead of the membrane system to prevent scale formation. Membrane elements fouled or damaged due to scale formation are not covered by the limited warranty.
General Handling Procedures
- Elements must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
- If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
- Permeate from the first hour of operation should be discarded to flush out the preservative solution.
- Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short-term storage (i.e., one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
- Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.