Datasheet summary
CSM RE8040-FE
Engineering summary from PDF text extraction for CSM RE8040-FE. Verify every value with the OEM datasheet.
Summary
Product identification
The RE8040-FEn is an enhanced fouling resistant reverse osmosis (RO) element designed for brackish water and wastewater reuse applications.
- Membrane type: Thin-Film Composite
- Membrane material: Polyamide (PA)
- Element configuration: Spiral-Wound, FRP Wrapping
- Model Name: RE8040-FEn
- Part Numbers: 40000308, 40000309
- Dimensions:
- Length: 40.0 inch (1,016 mm)
- Diameter: 8.0 inch (201 mm)
- Inner Diameter (C): 1.12 inch (28 mm)
- Weight: 15 kg
- Accessories per element: One brine seal, one interconnector (coupler), and four o-rings.
- Vessel compatibility: Fits nominal 8.0 inch (201 mm) I.D. pressure vessels.
Specifications
- Permeate flow rate: 10,500 GPD (39.7 m³/day)
- Permeate flow rate for each element may vary but will be no more than 15%.
- Nominal salt rejection: 99.7%
- Minimum salt rejection: 99.4%
- Effective membrane area: 400 ft² (37.2 m²)
Stated performance is based on the following test conditions (after 30 minutes of operation):
- 2,000 mg/L NaCl solution
- 225 psig (1.5 MPa) applied pressure
- 15% recovery
- 77 °F (25 °C)
- pH 6.5–7.0
Packaging: Elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution and individually packaged in a cardboard box.
Operating limits
- Max. Pressure Drop / Element: 15 psi (0.1 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 Mpa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
- Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
- Max. Operating Temperature: 113 °F (45 °C)
- Operating pH Range: 2.0–11.0
- CIP pH Range: 1.0–13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
Design Guidelines for Various Water Sources (Flux rates in gfd)
- Wastewater Conventional (SDI < 5): 8–12 gfd
- Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
- Seawater, Open Intake (SDI < 5): 7–10 gfd
- Seawater, Beach Well (SDI < 3): 8–12 gfd
- Surface Water (SDI < 5): 12–16 gfd
- Surface Water (SDI < 3): 13–17 gfd
- Well water (SDI < 3): 13–17 gfd
- RO permeate (SDI < 1): 21–30 gfd
Saturation Limits (Using Antiscalants)
- Langlier Saturation Index (LSI): <+1.5
- Stiff and Davis Saturation Index (SDSI): <+0.5
- CaSO₄: 230% saturation
- SrSO₄: 800% saturation
- BaSO₄: 6,000% saturation
- SiO₂: 100% saturation
General Handling Procedures
- Storage: Elements in boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
- Damaged Packaging: If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
- Initial Operation: Permeate from the first hour of operation should be discarded to flush out the preservative solution.
- Long-Term Storage/Shutdowns: Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade).
- Short-Term Storage: For short term storage (one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
- Moisture: Keep elements moist at all times after initial wetting.
- Pressure/Flow: Avoid excessive pressure and flow spikes.
- Chemical Compatibility: Only use chemicals compatible with the membrane elements and components. Use of incompatible chemicals may void the element limited warranty.
- Permeate Pressure: Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.