Datasheet summary
CSM RE8040-FE440
Engineering summary from PDF text extraction for CSM RE8040-FE440. Verify every value with the OEM datasheet.
Summary
Product identification
This is an enhanced fouling resistant RO element designed for brackish water and wastewater reuse.
- Model Name: RE8040-FEn440
- Membrane type: Thin-Film Composite
- Membrane material: Polyamide (PA)
- Element configuration: Spiral-Wound, FRP Wrapping
- Effective membrane area: 440 ft² (40.9 m²)
- Part Numbers:
- Inter-connector: 40000308
- Brine Seal: 40000309
- Packaging: All elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution and individually packaged in a cardboard box.
- Accessories: Each membrane element is supplied with one brine seal, one interconnector (coupler), and four o-rings.
Product water
The stated product performance is based on data taken after 30 minutes of operation at the following test conditions: 2,000 mg/L NaCl solution at 225 psig (1.5 MPa) applied pressure, 15% recovery, 77 °F (25 °C), and pH 6.5–7.0.
- Permeate flow rate: 11,500 GPD (43.5 m³/day)
- Nominal salt rejection: 99.7%
- Minimum salt rejection: 99.4%
Permeate flow rate for each element may vary but will be no more than 15%.
Operating limits
- Max. Pressure Drop / Element: 15 psi (0.1 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
- Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
- Max. Operating Temperature: 113 °F (45 °C)
- Operating pH Range: 2.0–11.0
- CIP pH Range: 1.0–13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
Feed water
Design Guidelines for Various Water Sources (Flux in gfd)
- Wastewater Conventional (SDI < 5): 8–12 gfd
- Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
- Seawater, Open Intake (SDI < 5): 7–10 gfd
- Seawater, Beach Well (SDI < 3): 8–12 gfd
- Surface Water (SDI < 5): 12–16 gfd
- Surface Water (SDI < 3): 13–17 gfd
- Well water (SDI < 3): 13–17 gfd
- RO permeate (SDI < 1): 21–30 gfd
Saturation Limits (Using Antiscalants) The following limits are typically accepted by proprietary antiscalant manufacturers. It is the user’s responsibility to ensure proper chemical(s) and concentration are dosed ahead of the membrane system to prevent scale formation.
- Langlier Saturation Index (LSI): < +1.5
- Stiff and Davis Saturation Index (SDSI): < +0.5
- CaSO₄: 230% saturation
- SrSO₄: 800% saturation
- BaSO₄: 6,000% saturation
- SiO₂: 100% saturation
Mechanical / hydraulic
- Dimensions:
- A (Length): 40.0 inch (1,016 mm)
- B (Diameter): 8.0 inch (201 mm)
- C (Inter-connector Length): 1.12 inch (28 mm)
- Weight: 15 kg
- Fit: All RE8040 elements fit nominal 8.0 inch (201 mm) I.D. pressure vessels.
- Central Pipe: RE8040-FEn440 element can also be made with a 1.5 inch (38mm) diameter central pipe.
General Handling Procedures
- Elements contained in the boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
- If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
- Permeate from the first hour of operation should be discarded to flush out the preservative solution.
- Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade).
- For short term storage (i.e. one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
- Permeate pressure must always be equal or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.