Datasheet summary
CSM RE8040-FEN440
Engineering summary from PDF text extraction for CSM RE8040-FEN440. Verify every value with the OEM datasheet.
Summary
Product Identification
The RE8040-FEn440 is an enhanced fouling resistant reverse osmosis (RO) element designed for brackish water and wastewater reuse applications.
General Features
- Fouling resistant
- High Permeate Flow and High Rejection
- Robustness and High Durability in a wide pH range
- Extended effective membrane area
Applications
- Municipal
- Industrial
- Water Reuse
Certification
- Certified to NSF/ANSI/CAN 61
Element Specifications
- Membrane Type: Thin-Film Composite
- Membrane Material: Polyamide (PA)
- Element Configuration: Spiral-Wound, FRP Wrapping
- Permeate Flow Rate: 12,000 GPD (45.4 m³/day)
- Nominal Salt Rejection: 99.7% (Minimum 99.5%)
- Effective Membrane Area: 440 ft² (40.9 m²)
Test Conditions
Performance specifications are based on the following test conditions:
- NaCl Solution: 2,000 mg/L
- Applied Pressure: 225 psig (1.55 MPa)
- Recovery: 15%
- Temperature: 77°F (25°C)
- pH: 6.5–7.0
- Permeate flow rate for each element may vary +25% / -15%.
Dimensions and Weight
- Model Name: RE8040-FEn440
- Length (A): 40.0 inch (1,016 mm)
- Diameter (B): 7.9 inch (200 mm)
- Interconnector ID (C): 1.12 inch (28.5 mm)
- Weight: 15kg
Accessories
- Each membrane element is supplied with one interconnector (coupler) and four O-rings.
- All RE8040 elements fit nominal 8.0 inch (203.2 mm) I.D. pressure vessels.
Part Numbers
- Inter-Connector: SWA01049
- Brine Seal: SWA01043
Operating Limits
- Max. Pressure Drop / Element: 15 psi (0.10 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
- Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
- Max. Operating Temperature: 113°F (45°C)
- Operating pH Range: 2.0 – 11.0
- CIP pH Range: 1.0 – 13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
General Handling Procedures
- Elements contained in the boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
- For WET-TYPE elements, the preservative solution (1% sodium metabisulfite solution) is added to prohibit the growth of micro-organisms.
- Permeate from the first hour of operation should be discarded.
- Stabilized salt rejection is generally achieved within 1~48 hours of continuous use.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
- Permeate pressure must always be equal or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
- The element shell is FRP (Fiber Reinforced Plastic). Be aware of glass fiber strands and use safety equipment.
Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.