Back to CMS Membranes
Toray logo

Datasheet summary

CSM RE8040-HUE440

Engineering summary from PDF text extraction for CSM RE8040-HUE440. Verify every value with the OEM datasheet.

Summary

Product identification

The RE8040-HUE440 is a high TOC rejection reverse osmosis (RO) element with an extended area, designed for ultra-pure water applications.

  • Membrane type: Thin-Film Composite
  • Membrane material: Polyamide (PA)
  • Element configuration: Spiral-Wound, FRP Wrapping

Specifications

  • Permeate flow rate: 10,000 GPD (37.9 m³/day)
    • Based on test conditions: 2,000 mg/L NaCl solution at 225 psig (1.5 MPa) applied pressure, 15% recovery, 77 °F (25 °C), pH 6.5–7.0.
    • Permeate flow rate for each element may vary but will be no more than 10% below the value shown.
  • Nominal salt rejection: 99.5%
    • Based on test conditions: 2,000 mg/L NaCl solution at 225 psig (1.5 MPa) applied pressure, 15% recovery, 77 °F (25 °C), pH 6.5–7.0.
  • Minimum salt rejection: 99.4%
  • IPA rejection: 96.0% after 2 hours of operation
    • Based on test conditions: 1,000 mg/L IPA solution at 225 psig (1.5 MPa) applied pressure, 15% recovery, 77 °F (25 °C), pH 6.5–7.0.
  • Effective membrane area: 440 ft² (40.9 m²)

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 Mpa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 66 gpm (15.0 m³/hr)
  • Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 3.0–10.0
  • CIP pH Range: 2.0–11.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Feed water

Design Guidelines for Various Water Sources

  • Wastewater Conventional (SDI < 5): 8–12 gfd
  • Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
  • Seawater, Open Intake (SDI < 5): 7–10 gfd
  • Seawater, Beach Well (SDI < 3): 8–12 gfd
  • Surface Water (SDI < 5): 12–16 gfd
  • Surface Water (SDI < 3): 13–17 gfd
  • Well water (SDI < 3): 13–17 gfd
  • RO permeate (SDI < 1): 21–30 gfd

Saturation Limits (Using Antiscalants)

  • Langlier Saturation Index (LSI): <+1.5
  • Stiff and Davis Saturation Index (SDSI): <+0.5
  • CaSO₄: 230% saturation
  • SrSO₄: 800% saturation
  • BaSO₄: 6,000% saturation
  • SiO₂: 100% saturation

Mechanical / Hydraulic

  • Dimensions:
    • A = 40.0 inch (1,016 mm)
    • B = 8.0 inch (203 mm)
    • C = 1.12 inch (28 mm)
  • All RE8040 elements fit nominal 8.0 inch (203 mm) I.D. pressure vessels.
  • Each membrane element comes with one brine seal, one interconnector (coupler), and two o-rings.

General Handling Procedures

  • Elements must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
  • If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
  • Permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short-term storage (i.e., one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data and complete specifications, the official OEM PDF revision used on the project must be consulted.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.