CSM RE8040-SHF400

Engineering summary from PDF text extraction for CSM RE8040-SHF400. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: RE8040 -SHF 400
  • Features: High productivity RO element with extended area for seawater and high salinity well water.
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, FRP Wrapping

Specifications

The stated product performance is based on data taken after 30 minutes of operation at the following test conditions:

  • 32,000 mg/L NaCl solution

  • 800 psig (5.5 MPa) applied pressure

  • 8% recovery

  • 77 °F (25 °C)

  • pH 6.5–7.0

  • Permeate Flow Rate: 9,700 GPD (36.7 m³/day)

    • Permeate flow rate for each element may vary but will be no more than 15%.
  • Nominal Salt Rejection: 99.7%

  • Minimum Salt Rejection: 99.6%

  • Effective Membrane Area: 400 ft² (37.2 m²)

Mechanical / Hydraulic

  • Dimensions:
    • A: 40.0 inch (1,016 mm)
    • B: 8.0 inch (201 mm)
    • C: 1.12 inch (28 mm)
  • Weight: 15 kg
  • Accessories: Each membrane element is supplied with one brine seal and one interconnector (coupler) with four o-rings.
  • Fit: All RE8040 elements fit nominal 8.0 inch (201 mm) I.D. pressure vessels.

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 1,200 psi (8.27 MPa)
  • Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
  • Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0–11.0
  • CIP pH Range: 1.0–13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Feed water

Design Guidelines (flux in gfd)

  • Wastewater Conventional (SDI < 5): 8–12 gfd
  • Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
  • Seawater, Open Intake (SDI < 5): 7–10 gfd
  • Seawater, Beach Well (SDI < 3): 8–12 gfd
  • Surface Water (SDI < 5): 12–16 gfd
  • Surface Water (SDI < 3): 13–17 gfd
  • Well water (SDI < 3): 13–17 gfd
  • RO permeate (SDI < 1): 21–30 gfd

Saturation Limits (Using Antiscalants)

  • Langlier Saturation Index (LSI): < +1.5
  • Stiff and Davis Saturation Index (SDSI): < +0.5
  • CaSO₄: 230% saturation
  • SrSO₄: 800% saturation
  • BaSO₄: 6,000% saturation
  • SiO₂: 100% saturation