Back to CMS Membranes
Toray logo

Datasheet summary

CSM RE8040-SHF440

Engineering summary from PDF text extraction for CSM RE8040-SHF440. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: RE8040-SHF440
  • Description: High productivity RO element with extended area for seawater and high salinity well water
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polyamide (PA)
  • Element Configuration: Spiral-Wound, FRP Wrapping
  • Nominal Salt Rejection: 99.7%
  • Minimum Salt Rejection: 99.6%
  • Permeate Flow Rate: 9,900 GPD (37.5 m³/day)
  • Effective Membrane Area: 440 ft² (40.9 m²)
  • Test Conditions (for stated performance):
    • NaCl solution: 32,000 mg/L
    • Applied Pressure: 800 psig (5.5 MPa)
    • Recovery: 8%
    • Temperature: 77 °F (25 °C)
    • pH: 6.5–7.0
  • Note: Permeate flow rate for each element may vary but will be no more than 15%.
  • Packaging: Vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution and individually packaged in a cardboard box.

Mechanical / hydraulic

  • Element Dimensions:
    • A: 40.0 inch (1,016 mm)
    • B: 8.0 inch (201 mm)
    • C: 1.12 inch (28 mm)
  • Weight: 15 kg
  • Part Numbers (Accessories):
    • Interconnector: 40000308
    • Brine Seal: 40000309
  • Included Accessories: One brine seal, one interconnector (coupler), and four o-rings.
  • Vessel Fit: Elements fit nominal 8.0 inch (201 mm) I.D. pressure vessels.

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 1,200 psi (8.27 MPa)
  • Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
  • Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0–11.0
  • CIP pH Range: 1.0–13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Feed water

  • Design Guidelines for Various Water Sources (Flux rates):
    • Wastewater Conventional (SDI < 5): 8–12 gfd
    • Wastewater Pretreated by UF/MF (SDI < 3): 10–14 gfd
    • Seawater, Open Intake (SDI < 5): 7–10 gfd
    • Seawater, Beach Well (SDI < 3): 8–12 gfd
    • Surface Water (SDI < 5): 12–16 gfd
    • Surface Water (SDI < 3): 13–17 gfd
    • Well water (SDI < 3): 13–17 gfd
    • RO permeate (SDI < 1): 21–30 gfd
  • Saturation Limits (Using Antiscalants):
    • Langlier Saturation Index (LSI): <+1.5
    • Stiff and Davis Saturation Index (SDSI): <+0.5
    • CaSO₄: 230% saturation
    • SrSO₄: 800% saturation
    • BaSO₄: 6,000% saturation
    • SiO₂: 100% saturation

Handling and Storage

  • Storage Environment: Elements in boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
  • Damaged Packaging: If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
  • Initial Operation: Permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Wet Storage: Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade). For short-term storage (one week or less), 1% by weight sodium metabisulfite solution is adequate.
  • General Operation Guidelines:
    • Keep elements moist at all times after initial wetting.
    • Avoid excessive pressure and flow spikes.
    • Only use chemicals compatible with the membrane elements and components.
    • Permeate pressure must always be equal to or less than the feed/concentrate pressure.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must match the specific OEM PDF revision used on the project.