Back to CMS Membranes
Toray logo

Datasheet summary

CSM UE1812

Engineering summary from PDF text extraction for CSM UE1812. Verify every value with the OEM datasheet.

Summary

Product identification

  • Type: UF elements for residential use
  • Membrane type: Thin-Film Composite
  • Membrane material: Polysulfone (PSF)
  • Element configuration: Spiral-Wound, Tape Wrapping

Specifications

Model NamePermeate Flow Rate GPD (L/day)Molecular Weight Cut Off
UE1810200 (757)100K
UE1812250 (946)100K
UE2010450 (1,703)100K

Stated product performance is based on data taken after 30 minutes of operation at the following test conditions:

  • Pure water (2 MΩ) at 20 psig applied pressure
  • 100% recovery
  • 77 °F (25 °C)

Additional notes:

  • Permeate flow rate for each element may vary but will be no more than 15%.
  • Dry type elements are vacuum leak tested using the San Diego Protocol.
  • Dry elements are packaged in a polyethylene bag.
  • Wet elements are packaged in a polyethylene bag containing SB(4g/L) + HCl(0.51g/L) solution.

Operating limits

  • Max. Operating Pressure: 125 psi (0.86 MPa)
  • Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0–11.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0

Mechanical / Hydraulic

Dimensions (All measurements are in inches)

Model NameABCDE
UE18100.670.5510.080.981.77
UE18120.670.5511.020.791.77
UE20100.670.5510.080.981.91

Certifications

  • Models UE1810 and UE2010 are tested and certified under NSF/ANSI standard 58, material requirement only.
  • Model UE1812 is excluded from this certification.

General Handling Procedures

  • Elements contained in the boxes must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
  • If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
  • Permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade).
  • For short term storage (i.e. one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
  • Keep elements moist at all times after initial wetting.
  • Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
  • Permeate pressure must always be equal or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official PDF datasheet. For contractual purposes, refer to the specific OEM PDF revision used on your project.