Product identification

  • Model Name: UE2010
  • Application: UF element for residential use
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polysulfone (PSF)
  • Element Configuration: Spiral-Wound, Tape Wrapping

Performance

The stated product performance is based on data taken after 30 minutes of operation at the following test conditions:

  • Pure water (2 MΩ) at 20 psig applied pressure

  • 100% recovery

  • 77°F (25°C)

  • Permeate flow rate for each element may vary +15% / -15%.

  • Permeate Flow Rate: 450 GPD (1,703 L/day)

  • Molecular Weight Cut Off (MWCO): 100K

Operating limits

  • Max. Operating Pressure: 125 psi (0.86 MPa)
  • Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
  • Max. Operating Temperature: 113°F (45°C)
  • Operating pH Range: 3.0 – 10.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0

Mechanical / hydraulic

  • Element Dimensions (UE2010):
    • A: 0.67 inch (17 mm)
    • B: 0.55 inch (14 mm)
    • C: 11.73 inch (298 mm)
    • D: 0.98 inch (25 mm)
    • E: 1.89 inch (48 mm)

Handling and storage

  • Elements are supplied as Wet-type, soaked in a preservative solution (1.0% food grade SBS, also described as 1% sodium metabisulfite solution) and vacuum sealed in a poly bag. All elements are individually boxed.
  • Elements in boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
  • Permeate from the first hour of operation should be discarded.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components; incompatible chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Certifications

  • Certified to NSF/ANSI 58