Back to CMS Membranes
Toray logo

Datasheet summary

CSM UE8040-PF

Engineering summary from PDF text extraction for CSM UE8040-PF. Verify every value with the OEM datasheet.

Summary

Product identification

This is a normal grade UF (Ultrafiltration) element designed for RO (Reverse Osmosis) pretreatment.

  • Model Name: UE8040-PF
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polysulfone (PSF)
  • Element Configuration: Spiral-Wound, FRP Wrapping
  • Molecular Weight Cut Off: 50K–100K (Daltons)
  • Effective Membrane Area: 400 ft² (37.2 m²)

Performance specifications

  • Permeate Flow Rate: 14,000 GPD (52.9 m³/day)

Test Conditions (for stated product performance):

  • Concentration: Pure water
  • Pressure: 20 psig
  • Temperature: 77 °F (25 °C)
  • pH: 6.5–7.0
  • Permeate flow rate for each element may vary but will be no more than 20%.

Packaging All elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution and individually packaged in a cardboard box.

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
  • Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0–11.0
  • CIP pH Range: 1.0–13.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0

Feed water

Design Guidelines for Various Water Sources:

  • Surface Water (SDI < 5): 10–15 gfd
  • Softened Water (SDI < 3): 15–20 gfd
  • RO permeate (SDI < 1): 21–30 gfd

Mechanical / hydraulic

  • Dimensions:
    • A: 40.0 inch (1,016 mm)
    • B: 8.0 inch (201 mm)
    • C: 1.12 inch (28 mm)
  • Weight: 15 kg
  • Part Numbers: 40000308, 40000309
  • Each membrane element is supplied with one brine seal, one interconnector (coupler), and four o-rings.
  • UE8040 elements fit nominal 8.0 inch (201 mm) I.D. pressure vessels.

General handling procedures

  • Elements must be kept dry at room temperature (7–32 °C; 40–95 °F) and should not be stored in direct sunlight.
  • If the polyethylene bag is damaged, a new preservative solution (sodium bisulfite) must be added and air-tight sealed to prevent drying and biological growth.
  • Permeate from the first hour of operation should be discarded to flush out the preservative solution.
  • Elements should be immersed in a preservative solution during storage, shipping, and system shutdowns to prevent biological growth and freezing. The standard storage solution contains 1% by weight sodium bisulfite or sodium metabisulfite (food grade).
  • For short term storage (i.e., one week or less), 1% by weight sodium metabisulfite solution is adequate for preventing biological growth.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components; use of incompatible chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.