Back to Filmtec Membranes
DuPont logo

Datasheet summary

BW30-PRO-400-34

Engineering summary from PDF text extraction for BW30-PRO-400-34. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: FilmTec™ BW30 PRO-400/34
  • Type: High Rejection and High Performance Industry-Standard Brackish Water Reverse Osmosis Membrane Element
  • Membrane Type: Polyamide Thin-Film Composite
  • Key Features:
    • Delivers consistent water quality and higher rejection and flow than previous generation BW30 product.
    • Based on historical BW30 Industry-standard RO membrane with decades of proven performance.
    • Excellent durability resulting in stable, long-term performance.
    • Enhanced fouling protection thanks to 34 mil feed spacer.
  • Key Applications:
    • Demineralization for industrial applications, such as: Power Generation, Steel & Metal, Chemical & Petrochemical.
    • Municipal water purification.

Operating limits

  • Maximum Operating Temperature: 113°F (45°C)
    • Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Maximum Operating Pressure: 600 psig (41 bar)
  • Maximum Pressure Drop:
    • Per Element: 15 psig (1.0 bar)
    • Per Pressure Vessel (Minimum 4 Elements): 50 psig (3.5 bar)
  • pH Range:
    • Continuous Operation: 2 - 11
    • Short-Term Cleaning (30 min.): 1 - 13

Feed water

  • Maximum Feed Flow: 75 gpm (17 m³/hr)
  • Maximum Feed Silt Density Index: SDI 5
  • Free Chlorine Tolerance: < 0.1 ppm
  • Standard Test Conditions: 2,000 ppm NaCl, 225 psi (15.5 bar), 77°F (25°C), pH 8 and 15% recovery.

Product water

  • Permeate Flow Rate: 11,000 gpd (42 m³/d)
    • Flow rates for individual elements may vary but will be no more than 15% below the value shown.
  • Stabilized Salt Rejection: 99.6%
  • Minimum Salt Rejection: 99.4%

Mechanical / hydraulic

  • Active Area: 400 ft² (37 m²)
  • Feed Spacer Thickness: 34 mil
  • Element Dimensions (inches (mm)):
    • A: 40.0 (1,016)
    • B (ID): 1.125 (29)
    • C: 7.9 (201)

General Information

  • Keep elements moist at all times after initial wetting.
  • The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
  • Avoid static permeate-side backpressure at all times.
  • Permeate obtained from the first hour of operation should be discarded.
  • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.
  • If operating limits and guidelines given in this bulletin are not strictly followed, the warranty will be null and void.
  • To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
  • This product may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.

Disclaimer: This summary is based solely on the provided text extract. The original PDF may contain additional figures, footnotes, or revisions not included here. Contractual data for any project must match the specific OEM PDF revision used on that project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.