Datasheet summary

BW30XFRLE-400/34

Engineering summary from PDF text extraction for BW30XFRLE-400/34. Verify every value with the OEM datasheet.

Summary

Product identification

The FilmTec™ BW30XFRLE-400/34 Element is a spiral-wound element with a polyamide thin-film composite membrane, designed for reverse osmosis plant managers and operators dealing with challenging waters and wastewaters. It offers an advanced membrane treatment with good water purity, improved fouling resistance, and low energy consumption.

Key features include:

  • Good salt rejection with 30% lower pressures.
  • Excellent silica, nitrate, and ammonium rejection.
  • Effective cleaning performance, robustness, and durability due to its widest cleaning pH range (1-13) and chemical tolerance.

Typical Properties

  • FilmTec™ Element: BW30XFRLE-400/34
  • Active Area: 400 ft² (37 m²)
  • Feed Spacer: 34-LDP
  • Permeate Flow Rate: 11,500 GPD (43.5 m³/d)
  • Typical Stabilized Salt Rejection: 99.3%
  • Minimum Salt Rejection: 99.1%

Standard Test Conditions (for permeate flow and salt rejection):

  • 2,000 ppm NaCl
  • 150 psi (10.3 bar)
  • 77°F (25°C)
  • pH 8
  • 15% recovery

Notes:

  • Flow rates for individual elements may vary by no more than ±15%.
  • Stabilized salt rejection is generally achieved within 24-48 hours of continuous use.
  • Active area is guaranteed ± 3%.

Mechanical / hydraulic

Dimensions – inches (mm)

FilmTec™ ElementA (in.)A (mm)B (in.)B (mm)C (in.)C (mm)
BW30XFRLE-400/3440.01,0161.125 ID29 ID7.9201
  • Element is designed to fit a nominal 8-inch (203-mm) I.D. pressure vessel.

Operating limits

  • Maximum Operating Temperature: 113°F (45°C)
    • Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Maximum Operating Pressure: 600 psig (41 bar)
  • Maximum Element Pressure Drop: 15 psig (1.0 bar)
  • pH Range – Continuous Operation: 2 – 11
  • pH Range – Short-Term Cleaning (30 min.): 1 – 13
  • Maximum Feed Silt Density Index (SDI): SDI 5
  • Free Chlorine Tolerance: < 0.1 ppm
    • The presence of free chlorine and other oxidizing agents can cause premature membrane failure. Residual free chlorine should be removed by pretreatment.

Customer Notice

The use of this product does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction depends on the complete system design, operation, and maintenance.


Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data and complete information, always refer to the official OEM PDF revision used on your project.