Summary

Product identification

DOW™ Specialty Membrane XUS180804 and XUS180802 Reverse Osmosis Elements are ultra-high pressure, high-rejection elements designed for industrial water purification.

Key features:

  • Up to 120 bar (1,740 psi), ultra-high feed pressure capability due to distinct element and membrane design.
  • Increases overall efficiency of Zero-Liquid-Discharge (ZLD) by achieving very high solute concentrations, helping to reduce the size of downstream thermal treatment.
  • Excellent for recovery of salts in process streams.
  • Robust DOW FILMTEC™ reverse osmosis (RO) membrane sheet.
  • 34 mil feed spacer to lessen the impact of fouling on the pressure drop across a vessel and to enhance cleaning effectiveness.

Mechanical / Hydraulic

Product Specifications

DOW™ Specialty MembraneActive Area (ft²)Active Area (m²)Feed Spacer Thickness (mil)Minimum ATD OD (in.)ATD included
DOW XUS180804605.6343.9Yes
DOW XUS180802181.7342.4Yes

Element Dimensions

DOW™ Specialty MembranesA (in.)A (mm)B (in.)B (mm)C (in.)C (mm)D (in.)D (mm)
XUS18080440.01,0161.03260.75 OD19 OD3.999
XUS18080240.01,0161.03260.75 OD19 OD2.563.5

Operating limits

  • Maximum Operating Temperature: 113°F (45°C)
    • Note: Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Maximum Operating Pressure at 30°C: 1,740 psig (120 bar)
  • Maximum Element Pressure Drop: 15 psig (1.0 bar)
  • pH Range, Continuous Operation: 2 – 11
  • pH Range, Short-Term Cleaning (30 min.): 1 – 13
  • Maximum Feed Silt Density Index (SDI): SDI 5
  • Free Chlorine Tolerance: < 0.1 ppm

Maximum Operating Pressure vs. Temperature

Temperature (°C)Pressure (bar)Pressure (psi)
51201,740
101201,740
151201,740
201201,740
251201,740
301201,740
351031,494
40901,305
45831,200

Clean in Place (CIP) Parameters

  • Maximum CIP Pressure: 15 to 75 psi (1 to 5 bar)
  • pH Range, Cleaning (< 45°C): pH1 – pH13
  • Hydrogen Peroxide Limit, Short-Term Cleaning: 1,000 ppm

General Information

  • Keep elements moist at all times after initial wetting.
  • To control the spread of biological growth during system shutdowns, it is recommended that elements be immersed in a preservative solution.
  • Refer to the "Dow Specialty Membrane Prorated Element Warranty" for warranty information.