Back to Filmtec Membranes
DuPont logo

Datasheet summary

XUS290504

Engineering summary from PDF text extraction for XUS290504. Verify every value with the OEM datasheet.

Summary

Product identification

  • DOW™ Specialty Membrane XUS290504 Nanofiltration Element.
  • High Temperature Nanofiltration Element offering distinct features:
    • Up to 70°C continuous operating temperature capability due to distinct element and membrane design.
    • Robust DOW FILMTEC™ nanofiltration membrane sheet.
    • The 34 mil feed spacer allows for maximum active membrane surface area while lessening the impact of fouling, reducing the pressure drop across the pressure vessel and enhancing cleaning effectiveness.
  • Typical applications include:
    • Waste brine recycling from sugar decolorization.
    • Concentration of thin juice sugars or components in chemical processing.
    • Sulfate removal in Chloralkali process streams.

Mechanical / hydraulic

  • DOW™ Specialty Membrane XUS290504
    • Active Area: 70 ft² (6 m²)
    • Feed Spacer Thickness: 34 mil
    • Minimum ATD OD: 3.9 in.
    • ATD included: Yes
  • Element Dimensions (XUS290504)
    • A: 40.0 in (1016 mm)
    • B: 1.03 in (26 mm)
    • C: 0.75 OD in (19 OD mm)
    • D: 3.9 in (99 mm)
  • DOW HYPERSHELL™ 4040 elements are designed to fit standard 4040 pressure vessels.

Operating limits

  • Maximum Operating Temperature: 70°C (158°F)
  • Maximum Operating Pressure at 80°C: 28 bar (406 psi)
  • Maximum Single Element Pressure Drop < 50°C: 0.9 bar (13.1 psi)
  • Maximum Single Element Pressure Drop < 80°C: 0.3 bar (4.4 psi)
  • Maximum Vessel Pressure Drop < 50°C: 4.1 bar (60 psi)
  • Maximum Vessel Pressure Drop < 80°C: 1.2 bar (17 psi)
  • pH Range, Continuous Operation (<35°C): pH2 – pH11
  • pH Range, Continuous Operation (35°C to 50°C): pH3 – pH10
  • pH Range, Continuous Operation (< 70°C): pH4 – pH8
  • Hydrogen Peroxide Limit: 20 ppm
  • Free Chlorine Tolerance: Below Detectable Limits
  • Maximum Feed Silt Density Index (SDI₁₅): SDI 5

Clean in Place (CIP) parameters

  • Maximum CIP Pressure: 15 to 75 psi (1 to 5 bar)
  • pH Range, Cleaning (45°C to 50°C): pH1.8 – pH11.0
  • pH Range, Cleaning (< 45°C): pH1 – pH13
  • Hydrogen Peroxide Limit, Short-Term Cleaning: 1,000 ppm

Important Start-Up Information

  • New elements are normally cleaned prior to initial use.
  • Avoid abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage.
  • During start-up, a gradual change from a standstill to operating state is recommended:
    • Feed pressure should be increased gradually over a 30-60 second timeframe.
    • Before initiating cross-flow at high permeate flux conditions, the set operating pressure should be maintained for 5-10 minutes.
    • Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.
    • Avoid permeate-side backpressure at all times.
    • Any concentrate or permeate obtained from the first hour of operation should be discarded.
  • Keep elements moist at all times after initial wetting.
  • To control the spread of biological growth during system shutdowns, it is recommended that elements be immersed in a preservative solution.