Summary

Product identification

The FilmTec™ Eco Pro-440i Element is a spiral-wound element featuring a polyamide thin-film composite membrane. It is described as ideal for reverse osmosis plant managers and operators dealing with controlled pre-treatment waters, seeking advanced membrane treatment with high water purity and low energy consumption.

Key features:

  • Offers high salt-rejection at low pressure.
  • Delivers excellent silica, boron, nitrate, TOC, and ammonium rejection.
  • Provides increased active area with effective cleaning performance, robustness, and durability due to its widest cleaning pH range (1–13) and chemical tolerance.
  • Includes iLEC™ interlocking end caps, which reduce system operating costs and the risk of O-ring leaks.

Typical Properties

  • Element: Eco Pro-440i
  • Active Area: 440 ft² (41 m²)
  • Feed Spacer Thickness: 28 mil
  • Permeate Flow Rate: 12,650 GPD (48 m³/d)
  • Typical Stabilized Salt Rejection: 99.7%
  • Minimum Salt Rejection: 99.4%

Standard test conditions: Permeate flow and salt (NaCl) rejection are based on 2,000 ppm NaCl, 150 psi (10.3 bar), 77°F (25°C), pH 8, 15% recovery. Stabilized salt rejection is generally achieved within 24–48 hours of continuous use.

Mechanical / hydraulic

Dimensions

Dimensions in inches (mm):

  • A: 40.0 inches (1,016 mm)
  • B: 40.5 inches (1,029 mm)
  • C: 7.9 inches (201 mm)
  • D: 1.125 ID (29 ID)

The element is designed to fit a nominal 8-inch (203-mm) I.D. pressure vessel. Individual elements with iLEC™ endcaps measure 40.5 inches (1,029 mm) in length (B). The net length (A) of the elements when connected is 40.0 inches (1,016 mm).

Operating limits

  • Maximum Operating Temperature: 113°F (45°C)
    • Note: Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Maximum Operating Pressure: 600 psig (41 bar)
  • Maximum Element Pressure Drop: 15 psig (1.0 bar)
  • pH Range:
    • Continuous Operation: 2 – 11
    • Short-Term Cleaning (30 min.): 1 – 13
  • Maximum Feed Silt Density Index (SDI): SDI 5
  • Free Chlorine Tolerance: < 0.1 ppm
    • Note: Under certain conditions, free chlorine and other oxidizing agents can cause premature membrane failure. Oxidation damage is not covered under warranty.

Important Information