Back to Filmtec Membranes
DuPont logo

Datasheet summary

DOW™ HYPERSHELL™ RO-8038/48

Engineering summary from PDF text extraction for DOW™ HYPERSHELL™ RO-8038/48. Verify every value with the OEM datasheet.

Summary

Product identification

DuPont reverse osmosis (RO) membrane elements, specifically the FilmTec™ Hypershell™ RO series, are designed for dairy processing applications, including dewatering and protein concentration. They contain sanitary, high-rejection FT30 reverse osmosis membranes suitable for a wide range of food, beverage, and dairy streams.

The FilmTec™ Hypershell™ RO-8038-FF, RO-8038/48-FF, and RO-390-FF are constructed with a polypropylene outer shell designed to:

  • Minimize channeling & fluid by-pass
  • Help prevent premature element failures throughout product lifetime
  • Improve hydrodynamics of the element
  • Comply with FDA Indirect Food Contact standards

The FilmTec™ Hypershell™ RO-390-FF product is highlighted as an industry premier membrane for permeate polishing, offering more active area than competitive elements to maximize performance and potentially reduce capital costs.

Hypershell™ elements require approximately 30% less flow than mesh wrap for an equivalent pressure drop (at 4 psi delta P), indicating potential energy savings.

Typical Properties

FilmTec™ ElementPart NumberActive Area ft² (m²)Feed Spacer milDesign Features
Hypershell™RO-8038302218370 (34.4)33Outer Shell Full Fit
Hypershell™RO-8038/48360400290 (27.0)48Outer Shell Full Fit
Hypershell™RO-390-FF346364390 (36.2)27Outer Shell Full Fit
RO-3838 / 30-FF8058981 (7.5)30Mesh Wrap Full Fit
RO-3840 / 30-FF10866485 (7.8)30Mesh Wrap Full Fit
RO-3938 / 30-FF11725985 (7.8)30Mesh Wrap Full Fit

Mechanical / hydraulic

Element Dimensions

FilmTec™ ElementA (in.)A (mm)B (in.)B (mm)C (in.)C (mm)
Hypershell™RO-8038¹38.00965.01.12528.587.9200
Hypershell™RO-8038/48¹38.00965.01.12528.587.9200
Hypershell™RO-390-FF²40.001,0161.12528.587.9200
RO-3838 / 30-FF38.00965.00.8321.13.896
RO-3840 / 30-FF40.001,0160.8321.13.896
RO-3938 / 30-FF38.00965.00.8321.13.996

¹ FilmTec™ Hypershell™ Elements are designed to fit schedule 40, 8-inch stainless pipe (nominal 7.98 inch ID). ² FilmTec™ Hypershell™ 390 Elements are designed in an 8040 style with 1-inch exposed product water tube instead of a flush cut end on each side.

Design Guidelines

FilmTec™ ElementMax. recirculation cross-flow gpm (m³/h)Max. element ΔP† psi (bar)
Hypershell™RO-803880 (18.2)13 (0.9)
Hypershell™RO-8038/4880 (18.2)13 (0.9)
Hypershell™RO-390-FF80 (18.2)13 (0.9)
RO-3838 / 30-FF30 (6.8)15 (1.0)
RO-3840 / 30-FF30 (6.8)15 (1.0)
RO-3938 / 30-FF30 (6.8)15 (1.0)

† Maximum pressure drop across entire vessel is 60 psi (4.1 bar).

Operating limits

  • Maximum Operating Pressure: 800 psig (54.8 bar)
  • Maximum Operating Temperature:
    • pH 2 – 10: 122°F (50°C)
    • Above pH 10: 95°F (35°C)
  • pH Range: pH 2 – 11
  • Free Chlorine Tolerance: Non-detectableᵇ
  • Hydrogen peroxide usage limitᵇ:
    • Continuous operation: 20 ppm
    • Short-term cleaning (@ 77°F/25°C maximum): 1,000 ppm

Clean in Place (CIP) Parameters

  • Maximum CIP Pressure: 15 – 75 psig (1 – 5 bar)
  • Maximum CIP Temperatureᵃ:
    • pH 1.8 – 11: 122°F (50°C)
    • pH 1.8 – 11.2: 113°F (45°C)
  • Free Chlorine Tolerance: Below Detectable Limitsᵇ
  • Hydrogen peroxide usage limitᵇ:
    • Continuous operation: 20 ppm
    • Short-term cleaning (@ 77°F/25°C maximum): 1,000 ppm

ᵃ Please consult DuPont Representative for operating & cleaning at different pH and temperature conditions. ᵇ Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. DuPont Water Solutions recommends removing residual free chlorine using pretreatment, prior to membrane exposure.

Additional Important Information

Review these additional resources for important information before use or storage:

  • Usage Guidelines for FilmTec™ 8” Elements (Form No. 45-D01706-en)
  • Start-Up Sequence (Form No. 45-D01609-en)
  • Storage and Shipping of New FilmTec™ Elements (Form No. 45-D01633-en)

Customer Notice

  • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.
  • Any concentrate or permeate obtained from the first hour of operation should be discarded.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.