DOW™ HYPERSHELL™ RO-8038
Engineering summary from PDF text extraction for DOW™ HYPERSHELL™ RO-8038. Verify every value with the OEM datasheet.
Summary
Product identification
DuPont Dairy RO Membranes are reverse osmosis elements specifically designed for dairy processing applications, offering state-of-the-art dewatering and protein concentration solutions. These elements utilize sanitary, high-rejection FT30 reverse osmosis membrane suitable for various food, beverage, and dairy streams.
The FilmTec™ Hypershell™ RO-8038-FF, RO-8038/48-FF, and RO-390-FF are constructed with a polypropylene outer shell designed to:
- Minimize channeling & fluid bypass
- Help prevent premature element failures throughout product lifetime
- Improve hydrodynamics of the element
- Comply with FDA Indirect Food Contact standards
The FilmTec™ Hypershell™ RO-390-FF product is highlighted as an industry premier membrane for permeate polishing, featuring more active area than competitive elements to maximize performance and reduce capital cost.
Compared to mesh wrap elements, FilmTec™ Hypershell™ elements have less exterior bypassing and require approximately 30% less flow for an equivalent pressure drop (at 4 psi delta P), which can lead to energy savings.
Typical Properties
| FilmTec™ Element | Part Number | Active Area ft² (m²) | Feed Spacer mil | Design Features |
|---|---|---|---|---|
| Hypershell™ RO-8038 | 302218 | 370 (34.4) | 33 | Outer Shell Full Fit |
| Hypershell™ RO-8038/48 | 360400 | 290 (27.0) | 48 | Outer Shell Full Fit |
| Hypershell™ RO-390-FF | 346364 | 390 (36.2) | 27 | Outer Shell Full Fit |
| RO-3838 / 30-FF | 80589 | 81 (7.5) | 30 | Mesh Wrap Full Fit |
| RO-3840 / 30-FF | 108664 | 85 (7.8) | 30 | Mesh Wrap Full Fit |
| RO-3938 / 30-FF | 117259 | 85 (7.8) | 30 | Mesh Wrap Full Fit |
Element Dimensions
| FilmTec™ Element | A (in.) | A (mm) | B (in.) | B (mm) | C (in.) | C (mm) |
|---|---|---|---|---|---|---|
| Hypershell™ RO-8038¹ | 38.00 | 965.0 | 1.125 | 28.58 | 7.9 | 200 |
| Hypershell™ RO-8038/48¹ | 38.00 | 965.0 | 1.125 | 28.58 | 7.9 | 200 |
| Hypershell™ RO-390-FF² | 40.00 | 1,016 | 1.125 | 28.58 | 7.9 | 200 |
| RO-3838 / 30-FF | 38.00 | 965.0 | 0.83 | 21.1 | 3.8 | 96 |
| RO-3840 / 30-FF | 40.00 | 1,016 | 0.83 | 21.1 | 3.8 | 96 |
| RO-3938 / 30-FF | 38.00 | 965.0 | 0.83 | 21.1 | 3.9 | 96 |
¹ FilmTec™ Hypershell™ Elements are designed to fit schedule 40, 8 inch stainless pipe (nominal 7.98 inch ID). ² FilmTec™ Hypershell™ 390 Elements are designed in an 8040 style with 1 inch exposed product water tube instead of a flush cut end on each side.
Operating limits
- Maximum Operating Pressure: 800 psig (54.8 bar)
- Maximum Operating Temperature:
- pH 2 – 10: 122°F (50°C)
- Above pH 10: 95°F (35°C)
- pH Range: pH 2 – 11
- Free Chlorine Tolerance: Non-detectable
- Hydrogen peroxide usage limit:
- Continuous operation: 20 ppm
- Short-term cleaning (@ 77°F/25°C maximum): 1,000 ppm
Clean in Place (CIP) Parameters
- Maximum CIP Pressure: 15 – 75 psig (1 – 5 bar)
- Maximum CIP Temperature:
- pH 1.8 – 11: 122°F (50°C)
- pH 1.8 – 11.2: 113°F (45°C)
- Free Chlorine Tolerance: Below Detectable Limits
- Hydrogen peroxide usage limit:
- Continuous operation: 20 ppm
- Short-term cleaning (@ 77°F/25°C maximum): 1,000 ppm
Mechanical / hydraulic
Design Guidelines
| FilmTec™ Element | Max. recirculation cross-flow gpm (m³/h) | Max. element ΔP† psi (bar) |
|---|---|---|
| Hypershell™ RO-8038 | 80 (18.2) | 13 (0.9) |
| Hypershell™ RO-8038/48 | 80 (18.2) | 13 (0.9) |
| Hypershell™ RO-390-FF | 80 (18.2) | 13 (0.9) |
| RO-3838 / 30-FF | 30 (6.8) | 15 (1.0) |
| RO-3840 / 30-FF | 30 (6.8) | 15 (1.0) |
| RO-3938 / 30-FF | 30 (6.8) | 15 (1.0) |
† Maximum pressure drop across entire vessel is 60 psi (4.1 bar).
Additional Information
Users should review additional resources for important information before use or storage, including:
- Usage Guidelines for FilmTec™ 8” Elements (Form No. 45-D01706-en)
- Start-Up Sequence (Form No. 45-D01609-en)
- Storage and Shipping of New FilmTec™ Elements (Form No. 45-D01633-en)
Effective cyst and pathogen reduction depends on the complete system design and its operation and maintenance. Any concentrate or permeate obtained from the first hour of operation should be discarded.
Disclaimer: This summary is based on the provided text extract. The original PDF datasheet may contain figures, footnotes, or revisions not present in this extract. For contractual purposes, always refer to the specific OEM PDF revision used for the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.