Datasheet summary
LC-HR-4040
Engineering summary from PDF text extraction for LC-HR-4040. Verify every value with the OEM datasheet.
Summary
Product identification
FilmTec™ LC 4040 Reverse Osmosis Elements are spiral-wound elements with a polyamide thin-film composite membrane, designed for commercial applications.
Two models are available:
- LC HR-4040: Produces high quality water with state-of-the-art RO membrane.
- Part Number: 343771 (Dry) / 343770 (Wet)
- LC LE-4040: Delivers high quality water at low pressure under harsh water conditions, using innovative proprietary technology for low energy applications.
- Part Number: 356603 (Dry) / 356602 (Wet)
Operating limits
- Membrane type: Polyamide Thin-Film Composite
- Maximum operating temperature: 113°F (45°C)
- Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Maximum operating pressure: 600 psig (41 bar)
- Maximum pressure drop: 15 psig (1.0 bar)
- Maximum feed flow rate: 16 gpm (3.6 m³/h)
- pH range:
- Continuous operation: 2 - 11
- Short-term cleaning: 1 – 13
- Maximum Feed Silt Density Index: SDI 5
- Free chlorine concentration: < 0.1 ppm
- DuPont recommends removing residual free chlorine and other oxidants by pretreatment.
- Maximum pressure drop across an entire pressure vessel (housing): 50 psi (3.4 bar)
Product water
Permeate flow and salt rejection based on test conditions: 2000 ppm NaCl, 77°F (25°C), 15% recovery, pH 8.
| Product | Feed Spacer Thickness (mil) | Permeate Flow Rate gpd (m³/d) | Min. Salt Rejection (%) | Stabilized Salt Rejection (%) | Applied Pressure |
|---|---|---|---|---|---|
| LC HR-4040 | 28 | 2900 (11) | 99.5 | 99.7 | 225 psig |
| LC LE-4040 | 28 | 2500 (9.5) | 99.0 | 99.2 | 125 psig |
- Permeate flows for individual elements may vary +/-15%.
- Permeate obtained from the first hour of operation should be discarded.
- The use of this product does not necessarily guarantee the removal of cysts and pathogens. Effective reduction depends on complete system design, operation, and maintenance.
LC HR-4040 Typical Solute Rejection
- NH₄⁺: 98.8%
- NO₃⁻: 98.2%
- SiO₂: 99.8%
- Boron: 80.0%
Mechanical / hydraulic
Element Dimensions (LC HR-4040 and LC LE-4040)
-
A: 40.00 inches (1016 mm)
-
B: 1.05 inches (26.7 mm)
-
C: 0.75 inches (19 mm)
-
D: 3.9 inches (99 mm)
-
Elements fit nominal 4-inch I.D. pressure vessel.
Operation Guidelines
- Avoid abrupt pressure or cross-flow variations during start-up, shutdown, cleaning, or other sequences.
- During start-up, a gradual change from a standstill to operating state is recommended:
- Feed pressure should be increased gradually over a 30 – 60 second time frame.
- Cross-flow velocity at the set operating point should be achieved gradually over 15 – 20 seconds.
- Keep elements moist at all times after initial wetting.
- To prevent biological growth during prolonged system shutdowns, elements should be immersed in a storage solution.
- Avoid static permeate-side backpressure at all times.