Datasheet summary
FILMTEC™ NF245-3840/30-FF
Engineering summary from PDF text extraction for FILMTEC™ NF245-3840/30-FF. Verify every value with the OEM datasheet.
Summary
Product Identification
DuPont nanofiltration (NF) membrane elements are designed for dairy processing applications, offering desalting, purification, and other separations for food and dairy processors. All NF245 elements incorporate an improved nanofiltration membrane sheet engineered to reject organics with a molecular weight above 300 amu while allowing monovalent salts to pass.
The FilmTec™NF245-3840/30-FF product features a Mesh Wrap Full Fit outer shell construction.
Operating Limits
- Maximum Operating Pressure: 800 psig (54.8 bar)
- Maximum Operating Temperature:
- pH 2 – 10: 122ºF (50ºC)
- Above pH 10: 95ºF (35ºC)
- pH Range: pH 2 – 11
- Free Chlorine Tolerance: Non-detectable
- Hydrogen Peroxide Usage Limit:
- Continuous operation: 20 ppm
- Short-term cleaning (@ 77°F/25°C maximum): 1,000 ppm
Cleaning Limits
- Maximum CIP Pressure: 15 – 75 psig (1 – 5 bar)
- Maximum CIP Temperature:
- pH 1.8 – 11: 122ºF (50ºC)
- pH 1.8 – 11.2: 113ºF (45ºC)
- Free Chlorine Tolerance: Below Detectable Limits
- Hydrogen Peroxide Usage Limit:
- Continuous operation: 20 ppm
- Short-term cleaning (@ 77°F/25°C maximum): 1,000 ppm
Mechanical / Hydraulic
For FilmTec™NF245-3840/30-FF:
- Active Area: 81 ft² (7.8 m²)
- Feed Spacer: 30 mil
- Element Dimensions:
- A: 38.75 in (984.0 mm)
- B: 0.83 in (21.1 mm)
- C: 3.8 in (96 mm)
- Maximum Recirculation Cross-Flow: 30 gpm (6.8 m³/h)
- Maximum Element ΔP (Pressure Drop): 15 psi (1.0 bar)
- Maximum Pressure Drop Across Entire Vessel: 60 psi (4.1 bar)
Product Water
The use of this product alone does not guarantee the removal of cysts and pathogens from water; effective reduction depends on the complete system design, operation, and maintenance. Any concentrate or permeate collected during the first hour of operation should be discarded.