Datasheet summary
NF270-4040
Engineering summary from PDF text extraction for NF270-4040. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: FilmTec™ NF270 Nanofiltration Elements for Commercial Systems
- Description: These elements are designed for removing a high percentage of Total Organic Carbon (TOC) and Trihalomethane (THM) precursors, offering medium to high salt passage and medium hardness passage. They are suitable for surface water and groundwater applications requiring good organic removal with partial softening.
- Membrane Type: Polyamide Thin-Film Composite
Performance Specifications
(Based on test conditions: 2,000 ppm MgSO₄, 77°F (25°C), 15% recovery, and specified pressure)
- NF270-2540
- Part Number: 149986
- Active Area: 28 ft² (2.6 m²)
- Applied Pressure: 70 psig (4.8 bar)
- Permeate Flow Rate: 850 gpd (3.2 m³/d)
- Stabilized Salt Rejection: >97.0%
- Individual element flow variation: -20% / +30%
- NF270-4040
- Part Number: 149987
- Active Area: 82 ft² (7.6 m²)
- Applied Pressure: 70 psig (4.8 bar)
- Permeate Flow Rate: 2,500 gpd (9.5 m³/d)
- Stabilized Salt Rejection: >97.0%
- Individual element flow variation: -15% / +50%
Operating limits
- Maximum Operating Temperature: 113°F (45°C)
- Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Maximum Operating Pressure: 600 psi (41 bar)
- Maximum Feed Flow Rate:
- 4040 elements: 16 gpm (3.6 m³/hr)
- 2540 elements: 6 gpm (1.4 m³/hr)
- Maximum Pressure Drop:
- tape wrapped elements: 13 psig (0.9 bar)
- fiberglassed elements: 15 psig (1.0 bar)
- Maximum pressure drop across an entire pressure vessel (housing): 30 psi (2.1 bar)
- pH Range:
- Continuous Operation: 2 - 11
- Short-Term Cleaning (30 min.): 1 - 12
- Maximum Feed Silt Density Index (SDI): 5
- Free Chlorine Tolerance: < 0.1 ppm (Removal of residual free chlorine by pretreatment prior to membrane exposure is recommended, as oxidation damage is not covered under warranty.)
Mechanical / hydraulic
Dimensions
- NF270-2540
- A: 40.0 in (1,016 mm)
- B: 1.19 in (30 mm)
- C: 0.75 in (19 mm)
- D: 2.4 in (61 mm)
- Outer wrap: Tape
- NF270-4040
- A: 40.0 in (1,016 mm)
- B: 1.05 in (27 mm)
- C: 0.75 in (19 mm)
- D: 3.9 in (99 mm)
- Outer wrap: Fiberglass
Operational Guidelines
- Avoid abrupt pressure or cross-flow variations.
- During start-up, feed pressure should be increased gradually over a 30-60 second timeframe.
- During start-up, cross-flow velocity at the set operating point should be achieved gradually over 15-20 seconds.
- Keep elements moist at all times after initial wetting.
- Avoid static permeate-side backpressure at all times.
- Permeate obtained from the first hour of operation should be discarded.
- To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data for specific projects must match the official OEM PDF revision.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.