Datasheet summary
SW30-8040
Engineering summary from PDF text extraction for SW30-8040. Verify every value with the OEM datasheet.
Summary
Product identification
- FILMTEC™ SW30-8040 Seawater Reverse Osmosis Element
- Membrane Type: Thin-Film Composite
Product water
- Product Specifications (based on 32,000 ppm NaCl, 5 ppm Boron, 800 psi (5.5 MPa), 77°F (25°C), pH 8 and 10% recovery):
- Active Area: 300 ft² (28 m²)
- Permeate Flow Rate: 6,000 gpd (23 m³/d)
- Minimum Salt Rejection: 98.6 %
- Stabilized Salt Rejection: 99.1 %
- Permeate flows for individual elements may vary +/-15%.
- Active area is guaranteed +/-5%.
Operating limits
- Maximum Operating Pressure: 1,015 psi (7.0 MPa)
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Feed Turbidity: 1 NTU
- Free Chlorine Tolerance: <0.1 ppm
- pH Range, Continuous Operation: 2 – 11
- pH Range, Short-Term Cleaning (30 min.): 1 – 13
- Maximum Feed Flow: 60 gpm (14 m³/h)
- Maximum Feed Silt Density Index (SDI): SDI 5
- Maximum pressure drop across an entire pressure vessel (housing): 50 psi (3.4 bar)
Mechanical / hydraulic
- Dimensions (SW30-8040):
- A: 40 inches (1,016 mm)
- B: 1.125 inches (29 mm)
- C: 7.9 inches (201 mm)
- Elements fit nominal 8-inch (203 mm) I.D. pressure vessel.
- Features: Fiberglass Outer Wrap, U-Cup Brine Seal, End Cap.
- Avoid any abrupt pressure or cross-flow variations during start-up, shutdown, or cleaning.
- Feed pressure should be increased gradually over a 30-60 second time frame during start-up.
- Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds during start-up.
- Permeate obtained from the first hour of operation should be discarded.
- Keep elements moist at all times after initial wetting.
- Avoid static permeate-side backpressure at all times.
- During prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution to prevent biological growth.
Disclaimer: The provided text is an extraction and may omit figures, footnotes, or the latest revisions. For contractual purposes, data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)