FilmTec™ SW30XFR-400/34(i)
Engineering summary from PDF text extraction for FilmTec™ SW30XFR-400/34(i). Verify every value with the OEM datasheet.
Summary
Product identification
The FilmTec™ SW30XFR-400/34i Element is a spiral-wound element featuring a polyamide thin-film composite membrane, specifically designed to handle biofouling in seawater desalination plants. It is equipped with advanced fouling-resistant and cleanability features, aiming to reduce the number of chemical cleanings and improve system uptime.
Key benefits include:
- Fouling-resistant design, reducing chemical cleanings by more than 33% relative to a leading fouling-resistant product.
- Durable membrane chemistry for stable, high rejection despite repeated chemical cleanings.
- Low element differential pressure, improving system hydraulic balance.
- More effective and efficient cleaning of biofilm, organic compounds, and scale, achieved through a wide pH range in cleaning (pH 1 – 13).
- Utilization of iLEC™ Interlocking Endcaps to help reduce system operating costs and O-ring leak risks.
Typical Properties
| FilmTec™ Element | Active Area (ft²) | Active Area (m²) | Feed Spacer Thickness (mil) | Permeate Flowrate (gpd) | Permeate Flowrate (m³/d) | Stabilized Boron Rejection (%) | Stabilized Salt Rejection (%) |
|---|---|---|---|---|---|---|---|
| SW30XFR-400/34i | 400 | 37 | 34 | 7,500 | 28 | 92 | 99.8 |
Normalized Conditions:
- 32,000 ppm NaCl, 5 ppm boron, 800 psi (5.5 MPa), 77°F (25°C), pH 8, 8% recovery.
- Permeate flows for individual elements may vary ± 15%.
- Minimum Salt Rejection is 99.65%.
- Stabilized salt rejection is generally achieved within 24–48 hours of continuous use.
- Active area guaranteed ± 5%.
Mechanical / hydraulic
Element Dimensions (inches (mm))
| FilmTec™ Element | A | A | B | B | C | C | D | D |
|---|---|---|---|---|---|---|---|---|
| SW30XFR-400/34i | 40.0 in. | 1,016 mm | 40.5 in. | 1,029 mm | 7.9 in. | 201 mm | 1.125 ID | 29 ID |
Notes:
- Element to fit nominal 8-inch (203-mm) I.D. pressure vessel.
- Individual elements with iLEC™ Interlocking Endcaps measure 40.5 inches (1,029 mm) in length (B).
- The net length (A) of the elements when connected is 40.0 inches (1,016 mm).
Operating limits
- Maximum Operating Temperature: 113°F (45°C) ᵃ, ᵇ
- Maximum Operating Pressure: 1,200 psig (83 bar) ᵇ
- Maximum Element Pressure Drop: 15 psig (1.0 bar)
- pH Range:
- Continuous Operation: 2 – 11 ᵃ
- Short-term Cleaning (30 min): 1 – 13 ᶜ
- Maximum Feed Silt Density Index (SDI): SDI₅
- Free Chlorine Tolerance: < 0.1 ppm ᵈ
Footnotes for Operating Limits:
- ᵃ Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- ᵇ Consult your DuPont representative for advice on applications above 95°F (35°C).
- ᶜ Refer to guidelines in Cleaning Guidelines (Form No. 45-D01696-en) for more information.
- ᵈ Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, residual free chlorine should be removed by pretreatment prior to membrane exposure.
Additional Important Information
Review the following resources before use or storage:
- Usage Guidelines for FilmTec™ 8” Elements (Form No. 45-D01706-en)
- Start-Up Sequence (Form No. 45-D01609-en)
- Storage and Shipping of New FilmTec™ Elements (Form No. 45-D01633-en)
Customer Notice
- The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction depends on complete system design and on the operation and maintenance of the system.
- Permeate obtained from the first hour of operation should be discarded.
Regulatory Note
This product may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
Disclaimer: This summary is an extraction from the provided text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual purposes, data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.