Back to Filmtec Membranes
DuPont logo

Datasheet summary

SW30XLE-400

Engineering summary from PDF text extraction for SW30XLE-400. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: FilmTec™ SW30XLE-400 Element
  • Product Type: Seawater Reverse Osmosis Element
  • Membrane Type: Spiral-wound element with polyamide thin-film composite membrane
  • Key Features:
    • High productivity, with an active area of 400 ft², designed for low total cost of water by optimizing energy consumption, system productivity, and operating flux.
    • Can be effectively used in permeate staged seawater desalination systems without impairing downstream stage performance.
    • Delivers high performance over its operating lifetime without oxidative post-treatments.
    • May be cleaned more effectively over a wider pH range (1 – 13) than other RO elements.
    • Automated, precision fabrication with a greater number of shorter membrane leaves to reduce overall fouling and maximize element efficiency.

Operating limits

  • Maximum Operating Temperature: 113°F (45°C)
    • Note: Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Maximum Operating Pressure: 1,200 psig (83 bar)
  • Maximum Element Pressure Drop: 15 psig (1.0 bar)
  • pH Range:
    • Continuous Operation: 2 – 11
    • Short-term Cleaning (30 min): 1 – 13

Feed water

  • Maximum Feed Silt Density Index (SDI): SDI 5
  • Free Chlorine Tolerance: < 0.1 ppm (DuPont recommends removing residual free chlorine by pretreatment prior to membrane exposure.)

Product water

  • Active Area: 400 ft² (37 m²) (guaranteed ± 5%)
  • Feed Spacer Thickness: 28 mil
  • Permeate Flowrate: 9,000 gpd (34 m³/d) (Individual element flows may vary ± 15%)
  • Stabilized Boron Rejection: 91.5%
  • Stabilized Salt Rejection: 99.8%
  • Minimum Salt Rejection: 99.6%
  • Test Conditions (Normalized):
    • 32,000 ppm NaCl
    • 5 ppm boron
    • 800 psi (5.5 MPa) operating pressure
    • 77°F (25°C) temperature
    • pH 8
    • 8% recovery
  • Note: Stabilized salt rejection is generally achieved within 24 – 48 hours of continuous use.

Mechanical / hydraulic

  • Element Dimensions (Nominal):
    • A: 40.0 inches (1,016 mm)
    • B (ID): 1.125 inches (29 mm)
    • C: 7.9 inches (201 mm)
  • Designed to fit a nominal 8-inch (203-mm) I.D. pressure vessel.

Important Operational Notes

  • Permeate obtained from the first hour of operation should be discarded.
  • The use of this product does not necessarily guarantee the removal of cysts and pathogens from water; effective reduction depends on complete system design, operation, and maintenance.
  • This product may be subject to drinking water application restrictions in some countries; users should check the application status before use and sale.

Disclaimer This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data for any project must match the specific OEM PDF revision used.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.