TW30-2013

Engineering summary from PDF text extraction for TW30-2013. Verify every value with the OEM datasheet.

Summary

Product identification

FilmTec™ Reverse Osmosis (RO) Elements are designed to provide high-quality water for small commercial systems, purifying less than one gallon per minute (0.2 m³/d) of RO water. These membranes are available in various sizes to suit different space requirements.

Key features include:

  • FilmTec™ XLE extra low energy elements operate at reduced pressure, contributing to lower energy costs and allowing for the use of lower-cost system components.
  • Delivers long-lasting and reliable performance.

Product Specifications

ProductPart NumberApplied Pressure psig (bar)Permeate Flow Rate gpd (m³/d)Stabilized Salt Rejection (%)
TW30-202680635225 (15.5)220 (0.83)99.5
TW30-251480639225 (15.5)200 (0.76)99.5
TW30-252180641225 (15.5)325 (1.23)99.5
XLE-2521154530100 (6.9)365 (1.38)99.0
TW30-401480605225 (15.5)525 (1.99)99.5
TW30-402180608225 (15.5)900 (3.41)99.5
XLE-4021154540100 (6.9)1,025 (3.88)99.0

Note 1: Permeate flow and salt rejection are based on specific test conditions:

  • TW30 elements: 2,000 ppm NaCl feed stream, pressure specified above, 77°F (25°C), and recovery rates (TW30-2026 – 10%; TW30-2521, XLE-2521, TW30-4021, XLE-4021 – 8%; TW30-2514, TW30-4014 – 5%).
  • XLE performance: 500 ppm NaCl feed stream, pressure specified above, 77°F (25°C), and recovery rates as above. Note 2: Permeate flows for individual elements may vary +/-20%.

Operating limits

  • Membrane Type: Polyamide Thin-Film Composite
  • Maximum Operating Temperature: 113°F (45°C)
    • Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Maximum Operating Pressure: 600 psig (41 bar)
  • Maximum Pressure Drop: 13 psig (0.9 bar)
  • pH Range:
    • Continuous Operation: 2 - 11
    • Short-Term Cleaning (30 min.): 1 - 13
  • Maximum Feed Silt Density Index (SDI): 5
  • Free Chlorine Tolerance: <0.1 ppm
    • Note: Presence of free chlorine and other oxidizing agents can cause premature membrane failure. Oxidation damage is not covered under warranty. Pretreatment to remove residual free chlorine is recommended.

Mechanical / hydraulic

Element Dimensions

ProductMaximum Feed Flow Rate gpm (m³/h)A - Length (Inches (mm))B - Permeate Tube OD (Inches (mm))C - Brine Seal OD (Inches (mm))D - Element OD (Inches (mm))
TW30-20265 (1.1)26.0 (660)1.18 (30)0.68 (17)1.8 (46)
TW30-25146 (1.4)14.0 (356)1.19 (30)0.75 (19)2.4 (61)
TW30-25216 (1.4)21.0 (533)1.19 (30)0.75 (19)2.4 (61)
XLE-25216 (1.4)21.0 (533)1.19 (30)0.75 (19)2.4 (61)
TW30-401414 (3.2)14.0 (356)1.05 (27)0.75 (19)3.9 (99)
TW30-402114 (3.2)21.0 (533)1.05 (27)0.75 (19)3.9 (99)
XLE-402114 (3.2)21.0 (533)1.05 (27)0.75 (19)3.9 (99)

Notes:

  • TW30-2026 has double o-rings on each end of the permeate tube.
  • TW30-2026 Elements fit nominal 2.0 inch pressure vessels.
  • TW30-2514, TW30-2521 and XLE-2521 Elements fit nominal 2.5 inch I.D. pressure vessels.
  • TW30-4014, TW30-4021, and XLE-4021 Elements fit nominal 4 inch I.D. pressure vessels.
  • Maximum pressure drop across an entire pressure vessel (housing) is 30 psi (2.1 bar).

General Information

  • Proper start-up of RO systems is essential to prevent membrane damage.
  • Avoid abrupt pressure or cross-flow variations during start-up, shutdown, or cleaning.
  • Gradual changes during start-up are recommended:
    • Feed pressure increased gradually over 30-60 seconds.
    • Cross-flow velocity achieved gradually over 15-20 seconds.
  • Keep elements moist at all times after initial wetting.
  • Operating limits and guidelines must be strictly followed to maintain warranty.
  • For prolonged system shutdowns, immerse membrane elements in a preservative solution to prevent biological growth.
  • Customers are responsible for the effects of incompatible chemicals and lubricants.
  • Avoid static permeate-side backpressure at all times.
  • The use of this product does not inherently guarantee the removal of cysts and pathogens; effective reduction depends on complete system design, operation, and maintenance.
  • Permeate obtained from the first hour of operation should be discarded.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. For contractual data and complete information, refer to the specific OEM PDF revision used on the project.