CPA5-LD-8040
Engineering summary from PDF text extraction for CPA5-LD-8040. Verify every value with the OEM datasheet.
Summary
Product identification
- Membrane Element: CPA5-LD (Low Fouling Technology)
- Configuration: Low Fouling Spiral Wound
- Membrane Polymer: Composite Polyamide
- Membrane Active Area: 400 ft² (37.1 m²)
- Feed Spacer: 34 mil (0.864 mm)
Performance
- Permeate Flow: 11,000 gpd (41.6 m³/d)
- Salt Rejection: 99.7 % (99.6 % minimum)
Performance is based on initial data (after 30 minutes of operation) under the following test conditions:
- 1500 PPM NaCl solution
- 225 psi (1.55 MPa) Applied Pressure
- 77 F (25 C) Operating Temperature
- 15% Permeate Recovery
- 6.5 - 7.0 pH Range
Permeate flow for individual elements may vary ±15 percent. Membrane active area may vary ±4%.
Operating limits
- Maximum Applied Pressure: 600 psig (4.16 MPa)
- Maximum Chlorine Concentration: < 0.1 PPM
- Maximum Operating Temperature: 113 F (45 C)
- pH Range, Continuous (Cleaning): 2-11 (1-13)
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Feedwater SDI (15 mins): 5.0
- Maximum Feed Flow: 75 GPM (17.0 m³/h)
- Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
- Maximum Pressure Drop for Each Element: 10 psi
The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.
Mechanical / hydraulic
- Dimensions:
- A: 40.0 inches (1016 mm)
- B: 7.89 inches (200 mm)
- C: 1.125 inches (28.6 mm)
- Weight: 36 lbs. (16.4 kg)
All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.