Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

ESNA1-LF2-LD-8040

Engineering summary from PDF text extraction for ESNA1-LF2-LD-8040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Membrane Element: ESNA1-LF2-LD (Low Fouling Technology)
  • Type: Low Fouling Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 400 ft² (37.1 m²)
  • Feed Spacer: 34 mil (0.864 mm)

Operating limits

  • Maximum Applied Pressure: 600 psig (4.16 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 F (45 C)
  • pH Range, Continuous (Cleaning): 2-10 (1-12)
  • Maximum Feed Flow: 75 GPM (17.0 m³/h)
  • Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
  • Maximum Pressure Drop for Each Element: 10 psi

Feed water

  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 4.0

Product water

  • Permeate Flow: 10,500 gpd (39.7 m³/d)
  • CaCl₂ Rejection: 86%
  • CaCl₂ Rejection (minimum/maximum): 83%/90%
  • Expected calcium rejection for a typical 500 ppm well water is 93% at 13 gfd operating flux and 25 C.
  • Permeate flow for individual elements may vary -20/+25 percent.

Mechanical / hydraulic

  • Dimensions:
    • A: 40.0 inches (1016 mm)
    • B: 7.89 inches (200 mm)
    • C: 1.125 inches (28.6 mm)
  • Weight: 36 lbs. (16.4 kg)
  • Membrane active area may vary +/-4%.
  • All membrane elements are supplied with a brine seal, interconnector, and o-rings.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium bisulfite solution, and then packaged in a cardboard box.

Performance Test Conditions

The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:

  • 500 ppm CaCl₂
  • 75 psi (0.52 MPa) Applied Pressure
  • 77 F (25 C) Operating Temperature
  • 15% Permeate Recovery
  • 6.5 – 7.0 Feed pH