Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

ESPA1

Engineering summary from PDF text extraction for ESPA1. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: ESPA1
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 400 ft² (37.2 m²)

All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Specified Performance

The specified performance is based on data taken after a minimum of 10 minutes of operation. Actual testing of elements may be done at conditions which vary from these exact values; in which case, the performance is normalized back to these standard conditions. Permeate flow for individual elements may vary +25 / -15 percent from the value specified.

  • Permeate Flow: 12,000 gpd (45.4 m³/d)
  • Salt Rejection: 99.4% (99.2% minimum)

Test Conditions:

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psig (1.03 MPa)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Operating Limits

The limitations shown here are for general use. For specified projects, operation at more conservative values may ensure the best performance and longest life of the membrane.

  • Maximum Applied Pressure: 600 psig (4.14 MPa)
  • Maximum Chlorine Concentration: < 0.1 ppm
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous (Cleaning): 2-10 (1-12)
  • Maximum Feed Flow: 75 gpm (17.0 m³/h)
  • Minimum Brine Flow: 12 gpm (2.7 m³/h)
  • Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)

Feed Water

  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0

Mechanical / Hydraulic

Values listed are indicative, not specified.

  • Element Length (A): 40.0 inches (1016 mm)
  • Element Diameter (B): 7.89 inches (200 mm)
  • Product Tube ID (C): 1.125 inches (28.6 mm)

Disclaimer: This Markdown summary is generated from an extracted text and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. For contractual data and complete specifications, the OEM PDF revision used on the project must be consulted.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.