Datasheet summary
ESPA2-LD-MAX
Engineering summary from PDF text extraction for ESPA2-LD-MAX. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Name: ESPA2-LD MAX
- Configuration: Low Fouling Spiral Wound
- Membrane Polymer: Composite Polyamide
Specified Performance
The Specified Performance is based on data taken after a minimum of 10 minutes of operation. Actual testing of elements may be done at conditions which vary from these exact values; in which case, the performance is normalized back to these standard conditions. Permeate flow for individual elements may vary ±15 percent from the value specified.
- Permeate Flow: 12,000 gpd (45.4 m³/d)
- Salt Rejection: 99.6% (99.5% minimum)
- Test Conditions:
- 1500 ppm NaCl solution
- 150 psig (1.03 MPa) Applied Pressure
- 77 °F (25 °C) Operating Temperature
- 15% Permeate Recovery
- 6.5 - 7.0 pH Range
General Product Description
Values listed are indicative, not specified.
- Membrane Active Area: 440 ft² (40.9 m²)
- Feed Spacer: 34 mil (0.86 mm)
- Packaging: All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.
Mechanical / Hydraulic
Element details are indicative, not specified.
- A: 40.0 inches (1016 mm)
- B: 7.89 inches (200 mm)
- C: 1.125 inches (28.6 mm)
Operating Limits
The limitations shown here are for general use. For specified projects, operation at more conservative values may ensure the best performance and longest life of the membrane.
- Maximum Applied Pressure: 600 psig (4.14 MPa)
- Maximum Chlorine Concentration: < 0.1 ppm
- Maximum Operating Temperature: 113 °F (45 °C)
- pH Range, Continuous (Cleaning): 2-10.6 (1-12)
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Feedwater SDI (15 mins): 5.0
- Maximum Feed Flow: 85 gpm (19.3 m³/h)
- Minimum Brine Flow: 12 gpm (2.7 m³/h)
- Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)
Disclaimer The information and data are presented in good faith and in lieu of all warranties. All express or implied warranties, including the warranties of merchantability and fitness for a particular purpose, are hereby disclaimed and excluded. Conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the appropriateness of Hydranautics' products for the user's specific end uses.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.