Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

ESPA4-8040

Engineering summary from PDF text extraction for ESPA4-8040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Membrane Element: ESPA4-8040
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 400 ft² (37.1 m²) (may vary ±4%)

Performance

Performance is initial, based on 30 minutes of operation under the following test conditions:

  • Test Solution: 500 PPM NaCl solution

  • Applied Pressure: 100 psig (0.7 MPa)

  • Operating Temperature: 77 °F (25 °C)

  • Permeate Recovery: 15%

  • pH Range: 6.5 - 7.0

  • Permeate Flow: 12,000 gpd (45.4 m³/d) (individual elements may vary ±15%)

  • Salt Rejection: 99.2 % (99.0 % minimum)

Operating limits

  • Maximum Applied Pressure: 600 psig (4.16 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous: 2-10
  • pH Range, Cleaning: 1-12
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 75 GPM (17.0 m³/h)
  • Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
  • Maximum Pressure Drop for Each Element: 10 psi

Mechanical / hydraulic

  • Length (A): 40.0 inches (1016 mm)
  • Diameter (B): 7.89 inches (200 mm)
  • Brine Seal Inner Diameter (C): 1.125 inches (28.6 mm)
  • Weight: 36 lbs (16.4 kg)

Packaging

All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution and 10% propylene glycol, then packaged in a cardboard box.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.