Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

HSMM1600-ES

Engineering summary from PDF text extraction for HSMM1600-ES. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: HYDRAsub®MAX- MBR HSMM1600-ES
  • Type: Submerged Ultrafiltration Membrane Module
  • Membrane Polymer: Polyvinylidene Fluoride (PVDF)
  • Pore Size (nominal): 0.05 µm

Mechanical / hydraulic

  • Configuration: Submerged Membrane
  • Fiber Orientation: Vertical
  • Filtrate Flow: Bi-directional
  • Number of Elements in Module: 40 (40 m² each)
  • Nominal Membrane Area per Module: 17,216 ft² (1600 m²)
  • Permeate Connections: (2)- 3” MNPT
  • Air Connections: (2)- 3” MNPT
  • Guide Pipe Connections: (2)- To fit 3” pipe
  • Typical Module Dry Weight: 2682 lbs (1216 kg)
  • Typical Module Wet Weight: 4226 lbs (1916 kg)
  • Operating Mode: Outside to Inside
  • Note: Cage is made of stainless steel 304.

Operating limits

  • Maximum Transmembrane Pressure (Vacuum): -6 psig (-0.41 bar)
  • Maximum Backwash Pressure: 2 psig (0.14 bar)
  • Maximum Instantaneous Chlorine Concentration: 5,000 ppm (for a maximum of 2 hours)
  • Maximum Chlorine Tolerance: 742,000 ppm-hrs (maximum chemical tolerance for estimated life span of membrane)
  • Operating Temperature Range: 41 - 104ºF (5 - 40º C)
  • Feed Water pH Range: 6.0 - 8.0
  • Cleaning pH Range: 1.0 - 11.0

Feed water

  • MLSS Range: 8,000 - 12,000 mg/L (in membrane tank at steady state for municipal wastewater)

Process Conditions

  • Operating Filtrate Flux: 4-20 gfd (7-34 lmh) (depends on temperature and application)
  • Peak Operating Flux: 30 gfd (51 lmh)
  • Chemically Enhanced Backwash (CEB) Flux: 2.4 gfd (4 lmh)
  • CEB Chemicals: NaOCl (refer to operating manual for chemical concentrations and cleaning frequencies)
  • Clean In Place (CIP) Flux: 2.4 gfd (4 lmh)
  • CIP Chemicals: NaOCl or Citric Acid (refer to operating manual for chemical concentrations and cleaning frequencies)