HSMM2400-ES

Engineering summary from PDF text extraction for HSMM2400-ES. Verify every value with the OEM datasheet.

Summary

Product identification

The HYDRAsub® MAX-MBR HSMM2400-ES is a submerged ultrafiltration membrane module.

Module specifications

  • Configuration: Submerged Membrane
  • Fiber Orientation: Vertical
  • Filtrate Flow: Bi-directional
  • Membrane Polymer: Polyvinylidene Flouride (PVDF)
  • Pore Size (nominal): 0.05 µm
  • Number of Elements in Module: 60 (40 m² each)
  • Nominal Membrane Area per Module: 25824 ft² (2400 m²)
  • Permeate Connections: (4)- 3” MNPT
  • Air Connections: (4)- 2” MNPT
  • Guide Pipe Connections: (2)- To fit 3” pipe
  • Typical Module Dry Weight: 3517 lbs (1595 kg)
  • Typical Module Wet Weight: 5634 lbs (2555 kg)

Operating limits

  • Maximum Transmembrane Pressure (Vacuum): -6 psig (-0.41 bar)
  • Maximum Backwash Pressure: 2 psig (0.14 bar)
  • Maximum Instantaneous Chlorine Concentration: 5,000 ppma (for a maximum of 2 hours)
  • Maximum Chlorine Tolerance: 742,000 ppm-hrs (maximum chemical tolerance for estimated life span of membrane)
  • MLSS Range: 8,000 - 12,000 mg/L (in membrane tank at steady state for municipal wastewater)
  • Operating Temperature Range: 41 - 104ºF (5 - 40º C)
  • Feed Water pH Range: 6.0 - 8.0
  • Cleaning pH Range: 1.0 - 11.0
  • Operating Mode: Outside to Inside

Process conditions

  • Operating Filtrate Flux: 4-20 gfd (7-34 lmh) (depends on temperature and application)
  • Peak Operating Flux: 30 gfd (51 lmh) (depends on temperature and application)
  • Chemically Enhanced Backwash (CEB) Flux: 2.4 gfd (4 lmh)
  • CEB Chemicals: NaOCl (refer to operating manual for chemical concentrations and cleaning frequencies)
  • Clean In Place (CIP) Flux: 2.4 gfd (4 lmh)
  • CIP Chemicals: NaOCl or Citric Acid (refer to operating manual for chemical concentrations and cleaning frequencies)

Mechanical / hydraulic

The module's cage is made of stainless steel 304, unless otherwise specified. Connections are in ANSI units.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.