Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

HSMM600-ES

Engineering summary from PDF text extraction for HSMM600-ES. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product: HYDRAsub®MAX-MBR Submerged Ultrafiltration Membrane Module
  • Model: HSMM600-ES

Module Specifications

  • Configuration: Submerged Membrane
  • Fiber Orientation: Vertical
  • Filtrate Flow: Bi-directional
  • Membrane Polymer: Polyvinylidene Fluoride (PVDF)
  • Pore Size (nominal): 0.05 µm
  • Number of Elements in Module: 15 (40 m² each)
  • Nominal Membrane Area per Module: 6456 ft² (600 m²)
  • Permeate Connections: (2)- 2” MNPT Connections
  • Air Connections: (2)- 2” MNPT Connections
  • Guide Pipe Connections: (2)- To fit 3” pipe
  • Typical Module Dry Weight: 1278 lbs (580 kg)
  • Typical Module Wet Weight: 1631 lbs (740 kg)

Operating limits

  • Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)
  • Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)
  • Maximum Instantaneous Chlorine Concentration: 5,000 ppma (for a maximum of 2 hours)
  • Maximum Chlorine Tolerance: 742,000 ppm-hrs (Maximum chemical tolerance for estimated life span of membrane)
  • MLSS Range: 8,000 - 12,000 mg/Lc (In membrane tank at steady state for municipal wastewater)
  • Operating Temperature Range: 41 - 104ºF (5 - 40º C)
  • Feed Water pH Range: 6.0 - 8.0
  • Cleaning pH Range: 1.0 - 11.0
  • Operating Mode: Outside to Inside

Typical Process Conditions

  • Operating Filtrate Flux†: 4-20 gfd (7-34 lmh)
  • Peak Operating Flux†: 30 gfd (51 lmh)
  • Chemically Enhanced Backwash (CEB) Flux: 2.4 gfd (4 lmh)
  • CEB Chemicals: NaOClᵈ
  • Clean In Place (CIP) Flux: 2.4 gfd (4 lmh)
  • CIP Chemicals: NaOCl or Citric Acidᵈ

† -Depends on temperature and application. ᵈ -Refer to operating manual for chemical concentrations and cleaning frequencies.

Mechanical / hydraulic

  • Cage Material: Stainless steel 304.
  • Connections: In English units.

Disclaimer

This summary is based on extracted text and may miss figures, footnotes, or the latest revisions. For contractual data, please refer to the specific OEM PDF revision used on your project.