Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

HSMM800-ES

Engineering summary from PDF text extraction for HSMM800-ES. Verify every value with the OEM datasheet.

Summary

Product identification

This is a HYDRAsub®MAX-MBR Submerged Ultrafiltration Membrane Module, model HSMM800-ES.

Module specifications

  • Configuration: Submerged Membrane
  • Fiber Orientation: Vertical
  • Filtrate Flow: Bi-directional
  • Membrane Polymer: Polyvinylidene Fluoride (PVDF)
  • Pore Size (nominal): 0.05 µm
  • Number of Elements in Module: 20 (40 m² each)
  • Nominal Membrane Area per Module: 8608 ft² (800 m²)
  • Permeate Connections: (2)- 2” MNPT Connections
  • Air Connections: (2)- 2” MNPT Connections
  • Guide Pipe Connections: (2)- To fit 3” pipe
  • Typical Module Dry Weight: 1478 lbs (670 kg)
  • Typical Module Wet Weight: 1880 lbs (853 kg)
  • Cage Material: Stainless steel 304

Operating limits

  • Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)
  • Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)
  • Maximum Instantaneous Chlorine Concentration: 5,000 ppm (for a maximum of 2 hours)
  • Maximum Chlorine Tolerance: 742,000 ppm-hrs (maximum chemical tolerance for estimated life span of membrane)
  • MLSS Range: 8,000 - 12,000 mg/L (in membrane tank at steady state for municipal wastewater)
  • Operating Temperature Range: 41 - 104ºF (5 - 40º C)
  • Feed Water pH Range: 6.0 - 8.0
  • Cleaning pH Range: 1.0 - 11.0
  • Operating Mode: Outside to Inside

Process conditions

  • Operating Filtrate Flux: 4-20 gfd (7-34 lmh) (depends on temperature and application)
  • Peak Operating Flux: 30 gfd (51 lmh) (depends on temperature and application)
  • Chemically Enhanced Backwash (CEB) Flux: 2.4 gfd (4 lmh)
  • CEB Chemicals: NaOCl (refer to operating manual for chemical concentrations and cleaning frequencies)
  • Clean In Place (CIP) Flux: 2.4 gfd (4 lmh)
  • CIP Chemicals: NaOCl or Citric Acid (refer to operating manual for chemical concentrations and cleaning frequencies)

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data for any project must match the specific OEM PDF revision used for that project.