Datasheet summary
HYDRAcap-MAX-4040
Engineering summary from PDF text extraction for HYDRAcap-MAX-4040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: HYDRAcap® MAX 4040
- Type: Capillary Ultrafiltration Module
- Configuration: Capillary Ultrafiltration Module
- Membrane Polymer: PVDF
- Nominal Membrane Area: 97 ft² (9 m²)
- Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
- Pore Size: 0.08 micron
Product water
- Filtrate Flow: 1.4 – 4.4 gpm (0.3 – 1.0 m³/h)
- Filtrate Turbidity: ≤ 0.10 NTU
- Bacteria Removal: ≥ 4 log
Operating limits
- Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)
- Maximum Applied Feed Pressure: 73 psig (5.0 bar) (at 68°F (20°C))
- Maximum Transmembrane Pressure: 30 psig (2.0 bar)
- Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
- Maximum Chlorine Exposure: 750,000 ppm-hrs
- Maximum Operating Temperature: 104 °F (40 °C)
- pH Operating Range: 4.0 – 10.0
- Cleaning pH Range: 1.0 – 13.0
Feed water
- Maximum Feed Turbidity: 300 NTU (Higher values can be treated; consult with Hydranautics’ technical staff.)
Mechanical / hydraulic
- Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode
- Dimensions (A): 44.88 inches (1140 mm)
- Dimensions (B): 41.42 inches (1052 mm)
- Feed Pipe Connection: 1” FNPT
- Filtrate Pipe Connections: ¾” FNPT
- Dry Weight: 25 lbs (11.3 kg)
- Wet Weight: 51 lbs (23.1 kg)
Typical Process Conditions
- Air Scour Rate: 1.3 – 1.6 acfm (2.2 – 2.7 m³/h)
- Air Scour Duration: 120 – 240 seconds
- Air Scour Frequency: Once every 20 – 60 minutes
- Maintenance Clean Frequency: 1 – 3 times per day
- Maintenance Clean Duration: 20 – 30 minutes
- Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
- Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid
Disclaimer: This summary is based solely on the extracted text. It may not include all figures, footnotes, or the latest revisions of the official OEM PDF datasheet. Contractual data for specific projects must match the OEM PDF revision used on that project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.