Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

HYDRAcap-MAX-60

Engineering summary from PDF text extraction for HYDRAcap-MAX-60. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: HYDRAcap® MAX 60
  • Configuration: Capillary Ultrafiltration Module
  • Membrane Polymer: TIPS PVDF
  • Nominal Membrane Area: 840 ft² (78 m²)
  • Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
  • Pore size: 0.08 micron
  • Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode
  • Certifications: NSF61, NSF419 (US LT2ESWTR – Public Drinking Water Compliance)

Operating limits

  • Maximum Applied Feed Pressure:
    • 73 psig (5.0 bar) at ≤20 °C
    • 58 psig (4 bar) between 21 – 30 °C
    • 44 psig (3 bar) between 31 – 40 °C
  • Maximum Transmembrane Pressure: 30 psig (2.0 bar)
  • Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
  • Maximum Chlorine Exposure: 1,000,000 ppm-hrs
  • Maximum Feed Turbidity: 300 NTU (Higher values can be treated; consult Hydranautics’ technical staff.)
  • Maximum Operating Temperature: 104 °F (40 °C)
  • pH Operating Range: 2.0 – 11.0
  • Cleaning pH Range: 1.0 – 13.0

Product water

  • Filtrate Flow: 11.7 – 37.9 gpm (2.7 – 8.6 m³/h)
  • Filtrate Turbidity: ≤ 0.10 NTU
  • Bacteria removal: ≥ 4 log
  • Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)

Mechanical / hydraulic

  • Dimensions:
    • A: 72.15 inches (1832.6 mm)
    • B: 63.11 inches (1602.9 mm)
    • C: 67.90 inches (1724.7 mm)
  • Pipe connections: 2” Victaulic
  • Dry Weight: 115 lbs (52 kg)
  • Wet Weight: 220 lbs (100 kg)

Process Conditions

  • Air Scour Rate: 7.3 – 9.1 acfm (12.3 – 15.4 m³/h)
  • Air Scour Duration: 120 – 240 seconds
  • Air Scour Frequency: Once every 20 – 60 minutes
  • Maintenance Clean Frequency: 1 – 3 times per day
  • Maintenance Clean Duration: 20 – 30 minutes
  • Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
  • Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.