
Datasheet summary
HYDRAcap-MAX-80
Engineering summary from PDF text extraction for HYDRAcap-MAX-80. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: HYDRAcap® MAX 80
- Configuration: Capillary Ultrafiltration Module
- Membrane Polymer: TIPS PVDF
- Nominal Membrane Area: 1130 ft² (105 m²)
- Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
- Pore Size: 0.08 micron
Performance
- Filtrate Flow: 15.7 – 51.0 gpm (3.6 – 11.6 m³/h)
- Filtrate Turbidity: ≤ 0.10 NTU
- Bacteria Removal: ≥ 4 log
- Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)
Operating limits
- Maximum Applied Feed Pressure:
- 73 psig (5.0 bar) at ≤20°C
- 58 psig (4.0 bar) between 21 – 30°C
- 44 psig (3.0 bar) between 31 – 40°C
- Maximum Transmembrane Pressure: 30 psig (2.0 bar)
- Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
- Maximum Chlorine Exposure: 1,000,000 ppm-hrs
- Maximum Feed Turbidity: 300 NTU (higher values can be treated; consult Hydranautics’ technical staff)
- Maximum Operating Temperature: 104 °F (40 °C)
- pH Operating Range: 2.0 – 11.0
- Cleaning pH Range: 1.0 – 13.0
- Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode
Process Conditions
- Air Scour Rate: 7.3 – 9.1 acfm (12.3 – 15.4 m³/h)
- Air Scour Duration: 120 – 240 seconds
- Air Scour Frequency: Once every 20 – 60 minutes
- Maintenance Clean Frequency: 1 – 3 times per day
- Maintenance Clean Duration: 20 – 30 minutes
- Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
- Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid
Mechanical / hydraulic
- Module Dimensions:
- A: 92.15 inches (2340.6 mm)
- B: 83.11 inches (2110.9 mm)
- C: 87.90 inches (2232.7 mm)
- Pipe Connections: 2” Victaulic
- Dry Weight: 135 lbs (62 kg)
- Wet Weight: 260 lbs (118 kg)
Certifications
- NSF61
- NSF419 (US LT2ESWTR – Public Drinking Water Compliance)
Disclaimer: This summary is based on text extracted from a PDF datasheet. This extraction may miss figures, footnotes, or revisions present in the original document. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.