Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

HYDRAcap-60 ACS

Engineering summary from PDF text extraction for HYDRAcap-60 ACS. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Type: Capillary Ultrafiltration Module
  • Configuration: Capillary Ultrafiltration Module
  • Membrane Polymer: Hydrophilic Polyethersulfone
  • Nominal Membrane Area: 500 ft² (46 m²)
  • Fiber Dimensions: ID 0.031” (0.8 mm), OD 0.055” (1.4 mm)
  • Pore Size: 0.02 micron

Performance

  • Filtrate Flow: 12.1 – 29.5 gpm (2.7 – 6.7 m³/h) †
  • Filtrate Turbidity: ≤ 0.07 NTU
  • Virus removal: ≥ 4 log
  • Bacteria removal: ≥ 4 log

Operating limits

  • Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m²/h) ‡
  • Maximum Applied Feed Pressure: 73 psig (5 bar) *
  • Maximum Transmembrane Pressure: 20 psig (1.4 bar)
  • Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
  • Instantaneous Chlorine Tolerance: 100 ppm**
  • Instantaneous Hydrogen Peroxide Tolerance: 200 ppm**
  • Maximum Chlorine Exposure: 200,000 ppm-hrs
  • Maximum Instantaneous Feed Turbidity: 100 NTU
  • Maximum Operating Temperature: 104 °F (40 °C)
  • pH Operating Range: 4.0 - 10.0
  • Cleaning pH Range: 1.5 – 13.0

* At 68°F (20°C). ** For 15 minutes or less. † Typical module performance for most feedwaters. ‡ The limitations shown here are for general use. The values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.

Process conditions

  • Operating Mode: Inside to Outside Filtration, Direct flow or Crossflow
  • Backwash Flux: 100 – 150 gfd (170 – 255 l/m²/h)
  • Backwash Duration: 30 – 60 seconds
  • Backwash Frequency: 20 – 60 minutes
  • Chemical Enhanced Backwash Frequency: 0 – 4 times per day
  • Chemical Enhanced Backwash Duration: 1 – 30 minutes
  • Disinfection Chemicals: NaOCl, H₂O₂, ClO₂ or NH₂Cl
  • Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid

Mechanical / hydraulic

  • Dimensions:
    • A: 63” (1600 mm)
    • B: 66 1/8” (1680 mm)
    • C: 67 1/4” (1708 mm)
  • Pipe connections: 2” Victaulic
  • Dry Weight: 80 lbs (36.3 kg)
  • Wet Weight: 155 lbs (70.3 kg)
    • Note: Weight stated is shipping weight including 1L of a 0.95% solution of sodium bisulfite preservative.

Certifications

  • ACS Verification

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data should always match the OEM PDF revision used on the project.