Datasheet summary
HYDRAcap60 E+
Engineering summary from PDF text extraction for HYDRAcap60 E+. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: HYDRAcap®60-E+ Capillary Ultrafiltration Module
- Configuration: Capillary Ultrafiltration Module
- Membrane Polymer: Hydrophilic Polyethersulfone
- Nominal Membrane Area: 605 ft² (56 m²)
- Fiber Dimensions: ID 0.031” (0.8 mm), OD 0.055” (1.4 mm)
- Pore Size: 0.02 micron
Performance
- Filtrate Flow†: 14.7 – 35.7 gpm (3.3 – 8.1 m³/h)
- Filtrate Turbidity: ≤ 0.07 NTU
- Virus removal: ≥ 4 log
- Bacteria removal: ≥ 4 log
Operating limits
- Maximum Applied Feed Pressure: 300 psig (20.7 bar)
- Maximum Transmembrane Pressure: 20 psig (1.4 bar)
- Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
- Instantaneous Chlorine Tolerance: 100 ppm**
- Instantaneous Hydrogen Peroxide Tolerance: 200 ppm**
- Maximum Chlorine Exposure: 200,000 ppm-hrs
- Maximum Instantaneous Feed Turbidity: 100 NTU
- Maximum Operating Temperature: 104 °F (40 °C)
- pH Operating Range: 4.0 - 10.0
- Cleaning pH Range: 1.5 – 13.0
- Typical Filtrate Flux Range‡: 35 – 85 gfd (59 – 145 l/m²/h)
Process conditions
- Operating Mode: Inside to Outside Filtration (Direct flow or Crossflow)
- Backwash Flux: 100 – 150 gfd (170 – 255 l/m²/h)
- Backwash Duration: 30 – 60 seconds
- Backwash Frequency: 20 – 60 minutes
- Chemical Enhanced Backwash Frequency: 0 – 4 times per day
- Chemical Enhanced Backwash Duration: 1 – 30 minutes
Cleaning and Disinfection Chemicals
- Disinfection Chemicals: NaOCl, H₂O₂, ClO₂, or NH₂Cl
- Cleaning Chemicals: HCl, H₂SO₄, NaOH, or Citric Acid
Mechanical / hydraulic
- Length: 59 1/8" (1502 mm)
- Diameter: Ø8 7/8 (225 mm)
- Dry Weight: 76 lbs (34.5 kg) (shipping weight including 1L of a 0.95% sodium bisulfite preservative solution)
- Wet Weight: 148 lbs (67.1 kg)
Certifications
- CA-DHS Verification
Notes:
- **For 15 minutes or less.
- † Typical module performance for most feedwaters.
- ‡ The limitations shown here are for general use. Values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.
Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.