Datasheet summary
HYDRAcap-60-LD
Engineering summary from PDF text extraction for HYDRAcap-60-LD. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Type: Capillary Ultrafiltration Module
- Model: HYDRAcap®60-LD
- Configuration: Capillary Ultrafiltration Module
- Membrane Polymer: Hydrophilic Polyethersulfone
- Nominal Membrane Area: 323 ft² (30 m²)
- Fiber Dimensions: ID 0.047” (1.2 mm), OD 0.08” (2.0 mm)
- Pore size: 0.02 micron
- Operating Mode: Inside to Outside Filtration, Direct flow or Crossflow
Product water
- Filtrate Flow: 7.8 – 19 gpm (1.8 – 4.3 m³/h)
- Filtrate Turbidity: ≤ 0.07 NTU
- Virus removal: ≥ 4 log
- Bacteria removal: ≥ 4 log
Operating limits
- Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m²/h)
- Maximum Applied Feed Pressure: 73 psig (5 bar) (at 68°F (20°C))
- Maximum Transmembrane Pressure: 20 psig (1.4 bar)
- Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
- Instantaneous Chlorine Tolerance: 100 ppm (for 15 minutes or less)
- Instantaneous Hydrogen Peroxide Tolerance: 200 ppm (for 15 minutes or less)
- Maximum Chlorine Exposure: 100,000 ppm-hrs
- Maximum Instantaneous Feed Turbidity: 200 NTU
- Maximum Operating Temperature: 104 F (40 C)
- pH Operating Range: 4.0 - 10.0
- Cleaning pH Range: 1.5 – 13.0
Process conditions
- Backwash Flux: 100 – 150 gfd (170 – 255 l/m²/h)
- Backwash Duration: 30 – 60 seconds
- Backwash Frequency: 20 – 60 minutes
- Chemical Enhanced Backwash Frequency: 0 – 4 times per day
- Chemical Enhanced Backwash Duration: 1 – 30 minutes
- Disinfection Chemicals: NaOCl, H₂O₂, ClO₂, or NH₂Cl
- Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid
Mechanical / hydraulic
- Dimensions:
- A: 63 inches (1600 mm)
- B: 66 1/8 inches (1680 mm)
- C: 67 1/4 inches (1708 mm)
- (See the official PDF for exact dimensions shown in the module diagram.)
- Pipe connections: 2” Victaulic
- Weight: 97 lbs. (44 kg) average (shipping weight including 1L of a 0.95% solution of sodium bisulfite preservative)
Certifications
- NSF61
- CDPH
- ETV-NSF Verification
Disclaimer: This summary is based on text extracted from an OEM PDF datasheet. It may not include all figures, footnotes, or the latest revisions. Contractual data for any project must match the specific OEM PDF revision used on that project.