Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

SanRO ESPA2

Engineering summary from PDF text extraction for SanRO ESPA2. Verify every value with the OEM datasheet.

Summary

Product identification

SanRO High Rejection RO Composite Membrane Elements are designed for high performance in USP and other high purity water systems. These elements feature sanitary, full-fit outer-wraps to eliminate "dead flow" areas for maximum bacteria control. SanRO components conform to FDA regulation CFR Title 21.

Product Performance

The following table provides performance characteristics for various SanRO membrane products.

ProductDescriptionPermeate Flow (GPD) / (m³/day) (8040)Permeate Flow (GPD) / (m³/day) (4040)% RejectionApplied Pressure (psig) / (MPa)Permeate TDS (PPM)
SanRO ESPA2High Rejection Energy Saver13000 (49.2)3300 (12.5)99.5136 (0.94)17.3
SanRO CPA3High Rejection Composite10500 (39.7)2600 (9.8)99.6158 (1.09)10.8
SanRO LFC3Low Fouling Composite9000 (34.1)2300 (8.7)99.6179 (1.23)9.0
SanRO CPA4High Rejection Composite5500 (20.8)1400 (5.3)99.6263 (1.81)5.2
  • Element Performance (Permeate Flow / Rejection) is measured at 225 psig (1.55 MPa), 1500 mg/L NaCl, 15% Recovery, and 77°F (25 °C).
  • System Performance (Applied Pressure and Permeate TDS) are projected values for a 2:2:1 array system operating at 15 GFD (26 LMH) average flux with 500 mg/L TDS feed (NaCl), 80% Recovery, pH 7, and 77°F (25 °C).

General Membrane Characteristics

  • Configuration: Sanitary (Full-Fit) Spiral Wound
  • Membrane Polymer: Composite Polyamide

Operating limits

  • Maximum Applied Pressure: 600 psig (4.14 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113°F (45 °C)
  • Operating pH Range: 3.0 - 10.0
  • Cleaning pH Range: 2.0 - 11.0
  • Maximum Pressure Drop for a vessel: 60 psig (0.41 MPa)

Note: These limitations are for general use. Values may be more conservative for specific projects to ensure optimal performance and membrane life.

Mechanical / hydraulic

The following table details the size and active area for different element sizes:

SizeA (in / cm)B (in / cm)C (in / cm)Area (ft² / m²)
404040.0 (102)3.98 (10.1)0.750 (1.9) O.D.90 (8.3)
804040.0 (102)7.90 (20.1)1.125 (2.9) I.D.380 (35.2)

Packaging

Elements are vacuum-sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, then packaged in a cardboard box.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. Contractual data must always match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.