Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

SWC1-4040

Engineering summary from PDF text extraction for SWC1-4040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Membrane Element: SWC1-4040
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Nominal Membrane Area: 70 ft²

Performance

  • Permeate Flow: 1,200 gpd (4.5 m³/d)
  • Minimum Rejection: 99.5%

Test Conditions for Stated Performance: The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:

  • 32,000 ppm NaCl
  • 800 psi (5.5 MPa) Applied Pressure
  • 77 °F (25 °C) Operating Temperature
  • 10% Permeate Recovery
  • 6.5 - 7.0 pH Range

Operating limits

  • Maximum Applied Pressure: 1000 psig (6.9 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop for Each Element: 10 psi

Feed water

  • Feedwater pH Range: 3.0 - 10.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 16 GPM (3.6 m³/h)
  • Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1

Mechanical / hydraulic

  • Dimensions (Nominal):
    • A: 40.00 inches (1016 mm)
    • B: 3.95 inches (100.3 mm)
    • C: 0.75 inches (19.1 mm)
  • Weight: 8 lbs. (3.6 kg)
  • Core tube extension: 1.05" (26.7 mm)

Notice:

  • Permeate flow for individual elements may vary ± 15 percent.
  • All membrane elements are supplied with a brine seal, interconnector, and o-rings.
  • Elements are vacuum-sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.